background image

9

 Safety Information

9.1 Safety Instructions

9.2 Maintenance and Warranty

9.1 Safety Instructions

General Instructions

l

Comply with all local laws and regulations when installing the hardware. The safety
instructions in this document are only supplemental to local laws and regulations.

l

The "DANGER", "WARNING", and "CAUTION" information in this document does
not represent all the safety instructions, but supplements to the safety instructions.

l

To ensure safety when installing hardware, follow all safety instructions provided on the
device labels and in this document.

l

Only qualified personnel are allowed to perform special tasks, such as performing high-
voltage operations and driving a forklift.

l

Take protective measures if a Class A product is used in residential areas as it is likely to
cause radio interference.

Personal Safety

l

Only personnel certified or authorized by Huawei are allowed to install the hardware.

l

Stop any operation that may cause personal injury or equipment damage, report the
problem to a project supervisor immediately, and take protective measures.

l

Do not operate the product or handle cables during thunderstorms.

l

Before carrying devices, note the following points:

Do not carry more weight than is permitted by local laws or regulations.

Ensue that there are enough people to carry the devices.

l

Wear clean protective gloves, ESD clothing, a protective hat, and protective shoes, as
shown in 

Figure 9-1

.

FusionServer Pro CH121 V5 Compute Node
User Guide

9 Safety Information

Issue 06 (2019-08-10)

Copyright © Huawei Technologies Co., Ltd.

123

Summary of Contents for FusionServer Pro CH121 V5

Page 1: ...FusionServer Pro CH121 V5 Compute Node V100R005 User Guide Issue 06 Date 2019 08 10 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...scribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the pre...

Page 3: ...mbol Description Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could...

Page 4: ...al specifications 04 2018 10 22 l Added procedure for installing an M 2 FRU l Added procedure for installing the supercapacitor 03 2018 05 14 l Added procedure for installing an NVMe drive l Added procedure for installing the BIOS battery l Added information about the Avago SAS3408 and Avago SAS3004 iMR RAID controller cards 02 2017 12 28 l Modified the memory module installation guidelines 01 201...

Page 5: ...3 3 Memory Compatibility 12 2 3 4 Memory Installation Guidelines 15 2 3 5 Memory Installation Positions 15 2 3 6 Memory Protection Technologies 17 2 4 Storage 17 2 4 1 Drive Configurations 17 2 4 2 Drive Numbering 17 2 4 3 Drive Indicators 18 2 4 4 RAID Controller Card 20 2 5 Network 20 2 5 1 LOMs 20 2 6 I O Expansion 21 2 6 1 PCIe Cards 21 2 6 2 PCIe Slot Description 22 2 7 Boards 23 2 7 1 Mainbo...

Page 6: ...equirements 72 4 2 Hardware Installation 72 4 2 1 Installation Overview 72 4 2 2 Unpacking the Compute Node 73 4 2 3 Installing Optional Parts 74 4 2 4 Installing the Compute Node 75 4 2 5 Connecting to Network 75 4 3 Initial Configuration 75 4 3 1 Default Information 75 4 3 2 Configuration Overview 77 4 3 3 Changing Initial Passwords 78 4 3 3 1 Changing the Initial Password of the Default iBMC Us...

Page 7: ...ftware and Configuration Utilities 117 8 1 Upgrading the System 117 8 2 MM910 118 8 3 iBMC 119 8 4 BIOS 120 8 5 FusionServer Tools uMate 121 9 Safety Information 123 9 1 Safety Instructions 123 9 2 Maintenance and Warranty 126 10 ESD 127 10 1 Preventing Electrostatic Discharge 127 10 2 Grounding Methods to Prevent Electrostatic Discharge 127 11 Product Specifications 129 11 1 Technical Specificati...

Page 8: ... Independent Remote Console 155 12 7 2 1 Windows 155 12 7 2 2 Ubuntu 157 12 7 2 3 macOS 159 12 8 Logging In to the CLI 161 12 8 1 Logging In to the CLI Using PuTTY over a Network Port 161 12 9 VMD Management 163 12 9 1 Enabling VMD 163 12 9 2 Disabling VMD 164 12 10 Clearing Data from a Storage Device 164 A More Information 167 A 1 Technical Support 167 A 2 Product Information 168 A 3 Product Conf...

Page 9: ...calability The CH121 V5 provides dense computing capability and an ultra large memory It is optimized for virtualization cloud computing high performance computing and compute intensive enterprise applications The CH121 V5 compute nodes are installed in an E9000 chassis and are centrally managed by the management module FusionServer Pro CH121 V5 Compute Node User Guide 1 Overview Issue 06 2019 08 ...

Page 10: ...Figure 1 1 CH121 V5 FusionServer Pro CH121 V5 Compute Node User Guide 1 Overview Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 2 ...

Page 11: ...h drive 5 Optional TPM 6 Screw in RAID controller card 7 Optional Supercapacitor 8 Heat sinks 9 Mainboard 10 Optional M 2 FRUsb 11 Drivesa 12 Optional M 2 adapterb 13 Drive cage 14 Processors 15 Mezzanine card 16 BIOS battery 17 Memory modules FusionServer Pro CH121 V5 Compute Node User Guide 1 Overview Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 3 ...

Page 12: ... other through two UPI links at a speed of up to 10 4 GT s l The mezzanine cards connect to the processors through PCIe buses to provide service ports l The Platform Controller Hub PCH has a built in MAC chip and provides two 10 Gbit s ports l The storage module consisting of a RAID controller card and a drive backplane connects to the CPUs through PCIe buses l The BMC provides device management f...

Page 13: ...ry 2 4 Storage 2 5 Network 2 6 I O Expansion 2 7 Boards 2 1 Front Panel 2 1 1 Appearance Figure 2 1 Front view with an M 2 module FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 5 ...

Page 14: ...es and mixed configuration of them l b An M 2 module is a 2 5 inch drive module that consists of one M 2 adapter and two M 2 FRUs 2 1 2 Indicators and Buttons Positions Figure 2 2 Indicators and buttons on the front panel 1 Power button indicator 2 UID button indicator 3 Health status indicator FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright H...

Page 15: ...and locate a device UID indicator l Off The device is not being located l Blinking blue The device has been located and is differentiated from other devices that have also been located l Steady blue The device is being located UID button l You can turn on or off the UID indicator by pressing the UID button or by using the iBMC or MM910 CLI or WebUI l You can press this button to turn on or off the...

Page 16: ...e check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected 2 1 4 Installation Positions The CH121 V5 is installed in a half width slot in the front of the E9000 chassis An E9000 chassis can house a maximum of 16 CH121 V5 compute nodes FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright H...

Page 17: ... socket CPU1 l The same model of processors must be used in a server l Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 9 ...

Page 18: ...fier You can determine the memory module properties based on the label attached to the memory module Figure 2 6 Memory identifier FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 10 ...

Page 19: ...l P 15 l T 17 7 DIMM type l R RDIMM l L LRDIMM 2 3 2 Memory Subsystem Architecture The CH121 V5 provides 24 memory slots Each processor integrates six memory channels Install the memory modules in the primary memory channels first If the primary memory channel is not populated the memory modules in secondary memory channels cannot be used Table 2 2 Memory channels CPU Memory Channel Memory Slot CP...

Page 20: ...01 2A2 2B primary DIMM110 2B1 2B DIMM111 2B2 2C primary DIMM120 2C1 2C DIMM121 2C2 2D primary DIMM130 2D1 2D DIMM131 2D2 2E primary DIMM140 2E1 2E DIMM141 2E2 2F primary DIMM150 2F1 2F DIMM151 2F2 2 3 3 Memory Compatibility Observe the following rules when configuring DDR4 memory modules FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright Huawei T...

Page 21: ...imum memory capacity supported by the CPUs l Use the Intelligent Computing Compatibility Checker to determine the capacity type of a single memory module l The maximum number of memory modules supported by a server varies depending on the CPU type memory type rank quantity and operating voltage NOTE Each memory channel supports a maximum of 8 ranks The number of memory modules supported by each ch...

Page 22: ...figured RAS features such as memory mirroring single device data correction SDDC SDDC 1 and double device data correction DDDC are not supported if x4 and x8 memory modules are used together Table 2 3 DDR4 memory specifications Parameter Specifications Rank Single rank Dual rank Quad rank Octal rank Rated speed MT s 2933a 2933a 2666 2666 Operating voltage V 1 2 1 2 1 2 1 2 Maximum number of DDR4 m...

Page 23: ...mory modules in vacant slots l Observe the following when configuring DDR4 memory modules in specific operating mode Memory sparing mode n Comply with the general installation guidelines n Each memory channel must have a valid online spare configuration n The channels can have different online spare configurations n Each populated channel must have a spare rank Memory mirroring mode n Comply with ...

Page 24: ...R4 memory installation guidelines 1 processor Figure 2 9 DDR4 memory installation guidelines 2 processors FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 16 ...

Page 25: ...onfiguration Maximum Drives Drive Management Mode Front drivesa 2b l Slots 0 and 2 support SAS SATA NVMe drives l M 2 FRUs can be installed only in slots 0 to 3 1 x RAID controller card l a Only 2 5 inch drives fit into the front slots l b Mixed configuration of M 2 modules and SAS SATA NVMe drives is supported l Contact your local Huawei sales representative or use the Intelligent Computing Compa...

Page 26: ...osition Blinking at 4 Hz Off Data is being read or written normally or data on the primary drive is being rebuilt Steady on Blinking at 1 Hz The drive is being located Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is being rebuilt Off Steady on A member drive in the RAID array is removed Steady on Steady on The drive is faulty FusionServer Pro CH121 V5 Compute Node User Guide 2...

Page 27: ...dy green The M 2 FRU is inactive NVMe SSD Indicators Figure 2 14 NVMe SSD indicators l If the VMD function is enabled and the latest Intel RSTe driver is installed NVMe SSDs support surprise hot swap Table 2 7 NVMe SSD indicators VMD enabled Green Indicator Yellow Indicator Description Off Off The NVMe SSD cannot be detected Steady green Off The NVMe SSD is working properly Blinking green at 2 Hz ...

Page 28: ... SSD is removable Steady green Off Steady yellow The NVMe SSD is faulty 2 4 4 RAID Controller Card The RAID controller card supports RAID configuration RAID level migration and drive roaming l Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used Table 2 9 RAID levels supported by the CH121 V5 RAID Level Reliabi...

Page 29: ...nabled for a LOM port the switch module connected to the LOM port must also have flow control enabled Table 2 10 I O modules supported by the LOM I O Module I O Module Slot LOM Remarks CX916 2X 3X 1E 4E The LOM cannot communicate with the I O modules in slots 1E and 4E CX920 2X 3X 1E 4E The LOM cannot communicate with the I O modules in slots 1E and 4E 2 6 I O Expansion 2 6 1 PCIe Cards l The serv...

Page 30: ... 17 00 00 18 0 0 00 LOM CPU 1 PCIe 3 0 x8 x8 Port1C 17 02 00 1c 00 0 0 Mezz1 CPU 1 PCIe 3 0 x16 or two x8 x16 or two x8 Port2A or Port2 A Port 2C 3a 00 0 3a 02 0 3b 00 0 3c 00 0 Mezz2 CPU 2 PCIe 3 0 x16 or two x8 x16 or two x8 Port2A or Port 2A Port2 C ae 00 0 ae 02 0 af 00 0 b0 0 0 0 PCIe Riser1 PCIe riser card 1 CPU 1 PCIe 3 0 x16 x16 Port3A 5d 00 0 5e 00 0 HHHL NVMe SSD0 disk 0 CPU 2 PCIe 3 0 x...

Page 31: ...t port of the processor l Device B D F indicates the B D F displayed on the OS of an onboard or extended PCIe device 2 7 Boards 2 7 1 Mainboard Figure 2 16 CH121 V5 mainboard 1 TPM connector 2 PCIe riser module connector PCIe 3 0 x16 3 PCIe riser module connector x8 4 RAID controller card connectors 5 Mezzanine card 2 connector 6 Mezzanine card 1 connector 7 BIOS battery 8 Positioning sleeve 9 Bac...

Page 32: ...e backplane connector 16 Drive cage 17 PCH 18 HLY indicator 19 UID button indicator 20 Power button indicator 21 USB 3 0 ports FusionServer Pro CH121 V5 Compute Node User Guide 2 Hardware Description Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 24 ...

Page 33: ...nstalling the Air Duct 3 9 Removing the PCIe Card Panel 3 10 Installing the PCIe Card Panel 3 11 Removing a PCIe Card 3 12 Installing a PCIe Card 3 13 Removing a SAS SATA Drive 3 14 Installing a SAS SATA Drive 3 15 Removing an NVMe Drive 3 16 Installing an NVMe Drive FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 25 ...

Page 34: ...f along with the chassis l Press the power button on the compute node front panel to power off the compute node gracefully For details see 2 1 2 Indicators and Buttons l Hold down the power button on the compute node front panel for six seconds to power off the compute node forcibly For details see 2 1 2 Indicators and Buttons l Use the MM910 WebUI For details see MM910 Management Module V100R001 ...

Page 35: ...red on in any of the following ways l If the compute node is installed but the chassis is not yet powered on power on the chassis The compute node will be powered on along with the chassis l If the chassis is powered on but the compute node is not installed install the compute node The compute node will be automatically powered on after it is installed l If the chassis is powered on but the comput...

Page 36: ...12 3 Logging In to the MM910 WebUI Step 3 On the HMM WebUI choose PSUs FANs The PSUs Fans page is displayed Step 4 Choose PSU Management Power Control from the navigation tree Figure 3 2 Power Control Step 5 Select the compute node to be powered on and click Power On The selected compute node will be powered on NOTE To power on all compute nodes at a time select the check box in the header row and...

Page 37: ...l injury hold the bottom of the device with both hands when removing it 1 Press the ejector release button on the compute node See 1 in Figure 3 4 2 Fully open the ejector lever See 2 in Figure 3 4 3 Holding the ejector lever pull the compute node out of the chassis horizontally See 3 in Figure 3 4 4 Close the ejector lever See 4 in Figure 3 4 FusionServer Pro CH121 V5 Compute Node User Guide 3 Ba...

Page 38: ...ll filler panels in vacant slots Otherwise the ventilation heat dissipation electromagnetic shielding and dustproof effects of the chassis will be affected Insert the filler panel into the chassis horizontally until it clicks into place FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 30 ...

Page 39: ...el End 3 4 Installing a CH121 V5 Procedure Step 1 Determine the position of the compute node in the chassis FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 31 ...

Page 40: ...y when filler panels are installed 1 Press and hold the groove inward on the filler panel to release the filler panel See 1 in Figure 3 7 2 Remove the filler panel from the chassis See 1 in Figure 3 7 FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 32 ...

Page 41: ... half width compute nodes Perform this operation only when no partition board is installed between two half width compute nodes a Tilt the partition board to the chassis insert it into the installation holes and make it upright See 1 and 2 in Figure 3 8 b Pull the partition board outwards See 3 and 4 in Figure 3 8 The partition board is properly installed when you hear a click FusionServer Pro CH1...

Page 42: ...hassis horizontally See 3 in Figure 3 9 5 Close the ejector lever See 4 in Figure 3 9 Figure 3 9 Installing a compute node Step 4 Power on the compute node For details see 3 2 Power On Procedure Step 5 Check indicator status For details see 2 1 2 Indicators and Buttons End FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd ...

Page 43: ...e button on the cover and push the cover backwards as far as it will go See 1 and 2 in Figure 3 10 2 Lift the chassis cover See 3 in Figure 3 10 Figure 3 10 Removing the cover End 3 6 Installing the Cover Procedure Step 1 Place the compute node on the ESD workstation Step 2 Take the spare part out of its ESD bag Step 3 Install the cover FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Ope...

Page 44: ...a CH121 V5 Step 5 Power on the compute node For details see 3 2 Power On Procedure End 3 7 Removing the Air Ducts Procedure Step 1 Power off the compute node For details see 3 1 Power Off Procedure Step 2 Remove the compute node For details see 3 3 Removing a CH121 V5 Step 3 Place the compute node on the ESD workstation Step 4 Remove the cover For details see 3 5 Removing the Cover Step 5 Determin...

Page 45: ... see 3 3 Removing a CH121 V5 Step 3 Place the compute node on the ESD workstation Step 4 Remove the cover For details see 3 5 Removing the Cover Step 5 Take the spare part out of its ESD bag Step 6 Determine the position of the air duct Step 7 Check whether a PCIe card is installed l If yes go to Step 8 l If no go to Step 9 Step 8 Transform the air duct FusionServer Pro CH121 V5 Compute Node User ...

Page 46: ...gure 3 13 Transforming the air duct Step 9 Align the right air duct with the right DIMMs align the left air duct with the left DIMMs and heat sinks and vertically place the air ducts downwards Figure 3 14 Installing the air duct FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 38 ...

Page 47: ... Step 2 Remove the compute node For details see 3 3 Removing a CH121 V5 Step 3 Place the compute node on the ESD workstation Step 4 Remove the cover For details see 3 5 Removing the Cover Step 5 Determine the position of the PCIe card panel Step 6 Loosen the two screws that secure the PCIe card panel and lift the PCIe card panel vertically See 1 and 2 in Figure 3 15 Figure 3 15 Removing a PCIe car...

Page 48: ...lled l If yes go to Step 6 l If no go to Step 7 Step 6 Remove the PCIe card For details see 3 11 Removing a PCIe Card Step 7 Take the spare part out of its ESD bag Step 8 Determine the position of the PCIe card panel Step 9 Install the PCIe card panel 1 Vertically slide the PCIe card panel into the slot and align the screw holes on the PCIe card panel with those on the pane See 1 in Figure 3 16 2 ...

Page 49: ...CIe Card Procedure Step 1 Power off the compute node For details see 3 1 Power Off Procedure Step 2 Remove the compute node For details see 3 3 Removing a CH121 V5 Step 3 Place the compute node on the ESD workstation Step 4 Remove the cover For details see 3 5 Removing the Cover Step 5 Remove the air duct For details see 3 7 Removing the Air Ducts FusionServer Pro CH121 V5 Compute Node User Guide ...

Page 50: ... screws that secure the PCIe card bracket and vertically lift the PCIe card bracket See 1 and 2 in Figure 3 18 2 Remove the PCIe card from the PCIe card bracket in the arrow direction See 3 in Figure 3 18 FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 42 ...

Page 51: ...immediately End 3 12 Installing a PCIe Card Procedure Step 1 Power off the compute node For details see 3 1 Power Off Procedure Step 2 Remove the compute node For details see 3 3 Removing a CH121 V5 Step 3 Place the compute node on the ESD workstation Step 4 Remove the cover For details see 3 5 Removing the Cover FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08...

Page 52: ...acket as far as it will go and ensure that the edge of the PCIe card is flush with the PCIe card bracket See 1 in Figure 3 20 2 Install the PCIe card bracket Ensure that the PCIe card connectors align with the connectors on the mainboard and the screw holes on the PCIe card filler panel align with the screw holes on the front panel See 2 in Figure 3 20 3 Tighten the three screws to secure the PCIe...

Page 53: ... cover For details see 3 6 Installing the Cover Step 12 Install the compute node For details see 3 4 Installing a CH121 V5 Step 13 Power on the compute node For details see 3 2 Power On Procedure End FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 45 ...

Page 54: ... SAS SATA drives support RAID configuration l If the drive to be removed is not in a RAID array or is in a RAID array without redundancy for example RAID 0 back up the data on the drive before removing it l If the drive to be removed is in a RAID array with redundancy you do not need to back up data before removing it Procedure Step 1 Determine the slot and position of the drive Figure 3 21 Positi...

Page 55: ...drive Step 5 Place the removed component in an ESD bag Step 6 Install a drive filler NOTE Perform this operation only when a drive is not installed immediately End 3 14 Installing a SAS SATA Drive l The SATA or SAS drives support hot swap After a faulty drive is disconnected from its backplane wait 30 seconds before removing it The alarm will not be cleared immediately after a new drive is install...

Page 56: ...is operation only when a drive filler is installed Step 4 Install a drive 1 Fully open the ejector lever and push the drive into the slot as far as it will go See 1 in Figure 3 24 2 Ensure that the ejector lever is fastened to the chassis beam and then close it to completely insert the drive into the slot See 2 in Figure 3 24 FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Iss...

Page 57: ... If the VMD function is disabled the NVMe drives support only orderly hot swap For details about how to disable the VMD function see 12 9 2 Disabling VMD Procedure VMD Enabled NOTE l Use the Intelligent Computing Compatibility Checker to obtain information about the operating systems supported by the VMD function l Before removing an NVMe drive l Stop accessing the NVMe drive l Back up date of the...

Page 58: ...lease the ejector lever See 1 in Figure 3 26 2 Open the drive ejector lever completely See 2 in Figure 3 26 3 Holding the ejector lever of the drive pull out the drive for about 3 cm 1 18 in Wait for at least 30 seconds and remove the drive from the server See 3 in Figure 3 26 Do not insert or remove drives frequently If a drive is frequently removed and installed in an interval shorter than 30 se...

Page 59: ... l Remove the NVMe drives one by one Remove the next NVMe drive only after the previous one is removed completely l Run command to uninstall the drive driver Windows OS NOTE l Use the Intelligent Computing Compatibility Checker to obtain information about the Windows operating systems supported l The following uses Windows Server 2012 R2 as an example Step 1 Determine the slot and position of the ...

Page 60: ... Computer Management Disk Management 2 Right click a drive and choose Properties from the shortcut menu In the displayed dialog box view the slot ID of the drive 3 Determine whether the drive is an NVMe drive based on the slot ID If yes record its drive letter as shown in Figure 3 28 Determine the physical slot of the drive based on the slot ID Table 3 1 lists the mapping between the slot IDs and ...

Page 61: ...nd NVMe tool NVMe Toolbox The NVMe Toolbox can be used to query NVMe drive information upgrade the firmware and perform hot swap NOTE After installing ES3000 V5 NVMe drives install the toolkit required by the OS to manage the drives The ES3000 V5 tool is incompatible with the built in NVMe driver of the Windows OS Therefore ensure that you have installed Huawei NVMe driver before using the tool Yo...

Page 62: ...d Eject Succeed will be displayed Figure 3 30 Success message NOTE If a failure message is displayed indicating that the NVMe drive is being accessed stop the related services and click eject again FusionServer Pro CH121 V5 Compute Node User Guide 3 Basic Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 54 ...

Page 63: ...r NOTE Perform this operation only when a drive is not installed immediately End Linux OS NOTE Use the Intelligent Computing Compatibility Checker to obtain information about the Linux operating systems supported Step 1 Determine the slot and position of the drive Figure 3 31 Positions of drives Step 2 Check the running status of the drive by observing its indicators For details see NVMe SSD Indic...

Page 64: ...EFI redhat grub cfg command In the command output find the sentence that is displayed after the cat proc cmdline command is executed in Step 4 a and add a space and then pciehp pciehp_force 1 pci pcie_bus_perf at the end of the sentence Do not add the content in a new line Figure 3 33 Configuring kernel parameters 1 Figure 3 34 Configuring kernel parameters 2 c Save the file and restart the comput...

Page 65: ...ommand In the command output find the sentence that is displayed after the cat proc cmdline command is executed in Step 4 a and add a space and then pciehp pciehp_force 1 pci pcie_bus_perf at the end of the sentence Do not add the content in a new line Figure 3 37 Configuring kernel parameters 1 Figure 3 38 Configuring kernel parameters 2 c Save the file and restart the compute node FusionServer P...

Page 66: ...vh kernel 3 10 0 514 26 2 e17 x86_64 rpm command to upload the upgrade package to the OS for installation d Restart the OS after the installation is complete e Run the uname r command If 3 10 0 514 26 2 el7 x86_64 is displayed the kernel is upgraded successfully Figure 3 41 Checking the kernel version l Example 2 SUSE 12 2 Upgrade the kernel of SUSE 12 2 to kernel default 4 4 74 92 32 1 x86_64 or ...

Page 67: ...nt Run find sys name nvme0n1 to query the bus number of the SSD device Run lspci vvv xxx s B D F grep i slot to query the slot No Figure 3 44 Querying the slot No B D F and slot ID Table 3 2 Mapping between physical slot numbers B D F and slot IDs Configuratio n Physical Slot No Root Port B D F Device B D F Slot ID 2 x 2 5 NVMe drive configuration Slot0 85 02 0 86 00 0 80 Slot2 85 03 0 87 00 0 81 ...

Page 68: ... is not f1 contact Huawei technical support b Change the value of the a8 register to e1 setpci s B D F a8 B e1 B D F indicates the root port B D F of the NVMe drive For details about the B D F information see Table 3 2 c Run the following command to check the modification result lspci xxx s B D F B D F indicates the root port B D F of the NVMe drive For details about the B D F information see Tabl...

Page 69: ...following command echo 0 sys bus pci slots 81 power 5 Observe the indicator status of the NVMe drive If the green indicator is off and the yellow indicator blinks at 0 5 Hz remove the NVMe drive slowly For details about the drive indicator status see NVMe SSD Indicators For details about how to manually remove an NVMe drive see 3 13 Removing a SAS SATA Drive 6 Place the removed component in an ESD...

Page 70: ...edure VMD Enabled NOTE l Use the Intelligent Computing Compatibility Checker to obtain information about the operating systems supported by the VMD function l Install the NVMe drives one by one Install the next NVMe drive only after the previous one is installed completely l If the OS is RHEL 7 3 and the VMD function is enabled the OS kernel 3 10 0 514 el7 x86_64 must be used for surprise hot swap...

Page 71: ...ou need to download the NVMe driver from the official Intel website for such Linux OSs For details about how to install the driver on the Linux OS see Intel_Linux_NVMe_Guide_330602 002 pdf obtained after the driver package is decompressed Driver download link https downloadcenter intel com download 28718 v t NOTE Download the NVMe driver of the latest version If no such driver is available use the...

Page 72: ...e drive is detected and working properly For details see NVMe SSD Indicators c Check the status of the newly installed NVMe drive in the system n If the drive status is normal no further action is required n If the newly installed NVMe drive cannot be identified perform Step 5 d to Step 5 e d Go to Device Manager and scan for hardware changes e Check the NVMe drive status on the OS l Linux a Slowl...

Page 73: ...ou need to download the NVMe driver from the official Intel website for such Linux OSs For details about how to install the driver on the Linux OS see Intel_Linux_NVMe_Guide_330602 002 pdf obtained after the driver package is decompressed Driver download link https downloadcenter intel com download 28718 v t NOTE Download the NVMe driver of the latest version If no such driver is available use the...

Page 74: ...rive is detected and working properly For details see NVMe SSD Indicators c Check the status of the newly installed NVMe drive in the system n If the drive status is normal no further action is required n If the newly installed NVMe drive cannot be identified perform Step 5 d to Step 5 e d Go to Device Manager and scan for hardware changes e Check the NVMe drive status on the OS l Linux a Configur...

Page 75: ...tput contains pciehp pciehp_force 1 pci pcie_bus_perf the kernel is configured successfully Figure 3 53 Checking the configuration n If SUSE 12 2 is installed in UEFI 1 Run the cat proc cmdline command If the command output does not contain pciehp pciehp_force 1 pci pcie_bus_perf you need to configure kernel parameters Figure 3 54 Opening the configuration file FusionServer Pro CH121 V5 Compute No...

Page 76: ... 3 Save the file and restart the compute node 4 Run the cat proc cmdline command If the command output contains pciehp pciehp_force 1 pci pcie_bus_perf the kernel is configured successfully Figure 3 57 Checking the configuration b Upgrade the OS kernel n Example 1 RHEL 7 3 Upgrade the kernel of RHEL 7 3 to kernel 3 10 0 514 26 2 e17 x86_64 or later to support orderly hot swap of NVMe drives 1 Run ...

Page 77: ...nel version n Example 2 SUSE 12 2 Upgrade the kernel of SUSE 12 2 to kernel default 4 4 74 92 32 1 x86_64 or later to support orderly hot swap of NVMe drives 1 Run the uname r command to check the current kernel version Figure 3 60 Kernel version 2 Log in to the official SUSE website to download the kernel upgrade package kernel 3 10 0 514 26 2 e17 x86_64 for example 3 Run the rpm ivh kernel defau...

Page 78: ...NOTE l When installing a supported OS on an NVMe drive load the NVMe driver for the system to enable the NVMe drives to be identified by the OS Then proceed with the OS installation l Only the UEFI mode supports OS installation on an NVMe drive 1 Set the UEFI mode a Press Del upon server startup to access the BIOS b Open the boot configuration screen and set Boot Type to UEFI Boot Type c Press F10...

Page 79: ...s of the cabinet l Do not block the air intake vents Otherwise air intaking and heat dissipation will be affected l The air conditioning system in the equipment room provides enough wind to ensure proper heat dissipation of all components 4 1 2 Temperature and Humidity Requirements To ensure continued safe and reliable equipment operation install or position the system in a well ventilated climate...

Page 80: ...roperly ground the server before installation to avoid damage to electronic components from electrostatic discharge Improper grounding may cause electrostatic discharge For details about how to prevent electrostatic discharge see 10 1 Preventing Electrostatic Discharge l Before installing multiple components read the installation instructions for all the components and identify similar actions to ...

Page 81: ...the seals or pressure sensitive adhesive tapes are not intact fill in the Cargo Problem Feedback Form Step 2 Use a box cutter to open the packing case Exercise caution with the box cutter to avoid injury to your hands or damage to devices Step 3 Unpack the packing case Figure 4 2 Unpacking the packing case FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation and Configuration Issue 06 ...

Page 82: ... End 4 2 3 Installing Optional Parts Before installing and configuring a compute node you need to install all optional parts required such as extra CPUs drives and mezzanine cards Procedure Step 1 Install the optional parts for the CH121 V5 For details see 5 2 Optional Parts End FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation and Configuration Issue 06 2019 08 10 Copyright Huawei ...

Page 83: ...nfigured for the compute node must match the switch module configured for the chassis Otherwise the network connection may fail 4 3 Initial Configuration 4 3 1 Default Information Table 4 2 Default information User Name User Descriptio n Default Password User Type User Status Login Method Administrat or An iBMC user NOTE iBMC does not have a default IP address Admin 900 0 Administrati ve User Enab...

Page 84: ...eyboard Video and Mouse No user name is used This applies to all compute nodes Admin 900 0 Administrati ve User Enabled Remote and local login Administrat or A user of the Secure Shell Daemon SSHD The SSH protocol allows a user to remotely log in to the host execution program implementin g secure management for the host Admin 900 0 Administrati ve User Enabled Remote and local login FusionServer P...

Page 85: ...that no alarm is generated for the compute node Set the iBMC IP address Set an iBMC IP address for the compute node Configure RAID Configure the corresponding RAID array based on service scenarios Configure the BIOS Configure the BIOS of the compute node including the boot mode NIC PXE function and BIOS password Install the OS Install an OS for the compute node FusionServer Pro CH121 V5 Compute No...

Page 86: ...t iBMC user on l MM910 WebUI For details see MM910 Management Module V100R001 User Guide l MM910 CLI For details see MM910 Management Module V100R001 Command Reference l iBMC WebUI For details see FusionServer Pro E9000 Server iBMC User Guide l iBMC CLI For details see FusionServer Pro E9000 Server iBMC User Guide NOTE l The default user name of the iBMC is Administrator and the default password i...

Page 87: ... current password select Modify Password and enter a new password in New Password and Confirm Password NOTE l The default user name of the iBMC is Administrator and the default password is Admin 9000 l This user is the default iBMC user who belongs to the administrator group This user has permission to access all iBMC resources and perform all operations Step 6 Click OK FusionServer Pro CH121 V5 C...

Page 88: ...r details see 2 1 2 Indicators and Buttons Step 2 Log in to the MM910 WebUI For details see 12 3 Logging In to the MM910 WebUI Step 3 Query version information 1 On the menu bar choose Chassis Information 2 Click the compute node in the specific slot and choose Version Information to query the version information of the compute node FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation ...

Page 89: ...sions meet site requirements If yes go to Step 4 If no go to Step 3 4 4 Upgrade the iBMC BIOS or CPLD For details see E9000 Server V100R001 Upgrade Guide Step 4 Query health status Step 5 Query alarm information 1 Click the compute node in the specific slot and choose Alarm List Figure 4 10 Querying alarm information 2 Check whether any alarm is generated If yes handle the alarms FusionServer Pro ...

Page 90: ...o the MM910 WebUI For details see 12 3 Logging In to the MM910 WebUI Step 2 Set the iBMC IP address To avoid conflicts with the network segment of the chassis management plane the iBMC IP address of the compute node cannot be configured in the 172 31 xx xx network segment If you need to configure the iBMC IP address change the IP addresses of the HMM and compute node in the network segment of the ...

Page 91: ...d varies depending on the RAID controller card model For details see Huawei V5 Server RAID Controller Card User Guide 4 3 7 Configuring the BIOS Scenarios This section describes how to configure the BIOS of the compute node To configure the BIOS perform the following operations l Set the system boot sequence l Set PXE for a NIC l Set the BIOS password l Select a language For details about other co...

Page 92: ... 2 On the Remote Virtual Console click on the menu bar Step 3 Select Reset or Forced System Reset Are you sure to perform this operation is displayed Step 4 Click Yes The compute node is restarted Step 5 During the restart press Delete or F4 when the information shown in Figure 4 13 is displayed FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation and Configuration Issue 06 2019 08 10 ...

Page 93: ...work press F12 Enter the password in the displayed dialog box l To access the Smart Provisioning GUI press F6 The screen for entering the BIOS password is displayed FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation and Configuration Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 85 ...

Page 94: ...node to unlock it The Main screen of the Setup Utility program is displayed End 4 3 7 1 2 Entering the BIOS Cascade Lake Procedure Step 1 Log in to the desktop of the compute node For details see 12 7 Logging In to the Desktop of a Server Step 2 On the Remote Virtual Console click on the menu bar Step 3 Select Reset or Forced System Reset Are you sure to perform this operation is displayed Step 4 ...

Page 95: ...TE l To go to the Boot Manager screen press F11 pr F3 l To boot from the network press F12 l To access the Smart Provisioning GUI press F6 The screen for entering the BIOS password is displayed FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation and Configuration Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 87 ...

Page 96: ...ord is entered three consecutive times You can restart the compute node to unlock it The Setup Utility program is started Step 7 Select BIOS Configuration by pressing arrow keys The Main screen is displayed End 4 3 7 2 Setting the System Boot Sequence If multiple boot devices are configured for the compute node you can set the system boot sequence on the BIOS Procedure Step 1 On the BIOS main scre...

Page 97: ...BIOS Parameter Reference Step 4 Select Boot Sequence and press Enter The Boot Sequence screen is displayed NOTE The default boot sequence is Hard Disk Drive DVD ROM Drive PXE Others Step 5 Select the target boot device and press F5 or F6 to change the boot order l Press F5 to move a boot option down l Press F6 to move a boot option up NOTE The server boots in the order specified on this screen End...

Page 98: ...tem will be locked if an incorrect password is entered three consecutive times You can unlock the system by restarting it l The default BIOS password is Admin 9000 l The requirements for setting the administrator password are as follows The password must be a string of 8 to 16 characters and contain special characters including spaces and at least two types of uppercase letters lowercase letters a...

Page 99: ...nges Exit dialog box is displayed Step 2 Select Yes and press Enter Settings are saved and the BIOS is exited The compute node automatically restarts for the settings to take effect End 4 3 8 Installing an OS The CH121 V5 supports multiple types of OSs l Use Intelligent Computing Compatibility Checker to obtain information about the compatible operating systems FusionServer Pro CH121 V5 Compute No...

Page 100: ...varies with the operating system For details see Huawei Server OS Installation Guide FusionServer Pro CH121 V5 Compute Node User Guide 4 Installation and Configuration Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 92 ...

Page 101: ... before installation to avoid damage to electronic components from electrostatic discharge Improper grounding may cause electrostatic discharge l Before touching a device wear ESD clothing and ESD gloves or wrist strap and remove conductive objects such as watches and jewelry For details see 9 1 Safety Instructions 5 2 Optional Parts 5 2 1 Installing an M 2 FRU Procedure Step 1 Determine the posit...

Page 102: ...e M 2 FRU Install filler panels in vacant slots to ensure optimal shielding for EMC 1 Holding the handle of the M 2 FRU push the M 2 FRU in the M 2 adapter slot See 1 in Figure 5 2 2 Close the M 2 FRU handle See 2 in Figure 5 2 Figure 5 2 Installing an M 2 FRU FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part Installation Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 94 ...

Page 103: ...ion Step 4 Remove the cover For details see 3 5 Removing the Cover Step 5 Check whether a PCIe card is installed l If yes go to Step 6 l If no go to Step 7 Step 6 Remove the PCIe card For details see 3 11 Removing a PCIe Card Step 7 Take the spare part out of its ESD bag Step 8 Determine the position of the screw in RAID controller card Figure 5 3 Position of the screw in RAID controller card Fusi...

Page 104: ... the PCIe card For details see 3 12 Installing a PCIe Card Step 14 Install the cover For details see 3 6 Installing the Cover Step 15 Install the compute node For details see 3 4 Installing a CH121 V5 Step 16 Power on the compute node For details see 3 2 Power On Procedure Step 17 Configure the RAID controller card The following uses the LSI SAS3008IR RAID controller card as an example 1 Log in to...

Page 105: ...t out of its ESD bag Step 7 Determine the position of the Avago SAS3004iMR RAID controller card Step 8 Install the Avago SAS3004iMR RAID controller card For details see 3 12 Installing a PCIe Card Step 9 Install the M 2 FRU on the Avago SAS3004iMR RAID controller card For details see 5 2 4 Installing an M 2 FRU on the Avago SAS3004iMR PCIe RAID Controller Card Step 10 Install the air duct For deta...

Page 106: ...e of the M 2 FRU and push the M 2 FRU into the slot of the Avago SAS3004iMR RAID control card See 1 in Figure 5 5 3 Close the handle of the M 2 FRU See 2 in Figure 5 5 Figure 5 5 Installing an M 2 FRU End 5 2 5 Installing the Supercapacitor Procedure Step 1 Power off the compute node For details see 3 1 Power Off Procedure Step 2 Remove the compute node For details see 3 3 Removing a CH121 V5 Step...

Page 107: ... 7 Install the supercapacitor holder 1 Place the supercapacitor holder vertically on the RAID controller card See 1 in Figure 5 7 2 Align the screws of the supercapacitor holder with the screw holes on the RAID controller card and tighten the screws See 2 in Figure 5 7 FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part Installation Issue 06 2019 08 10 Copyright Huawei Technologies C...

Page 108: ...ble to the supercapacitor See 2 in Figure 5 8 Figure 5 8 Installing the supercapacitor Step 9 Install the cover For details see 3 6 Installing the Cover Step 10 Install the compute node For details see 3 4 Installing a CH121 V5 Step 11 Power on the compute node For details see 3 2 Power On Procedure End FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part Installation Issue 06 2019 08...

Page 109: ...l the mezzanine cards 1 Align the lower mezzanine card with the positioning holes and metallic studs on the mounting base and press the mezzanine card vertically downwards into the connector on the mainboard See 1 in Figure 5 10 2 Tighten the two captive screws c and d shown in Figure 5 10 to secure the lower mezzanine card 3 Align the upper mezzanine card with the positioning holes and metallic s...

Page 110: ...zzanine cards l BIOS configuration For details see the user guide of the mezzanine card you use l OS configuration For details see the user guide of the mezzanine card you use l Switch configuration For details see the configuration guide of the switch you use l FC configuration For details see the configuration guide of the FC disk array you use Step 12 Check whether the mezzanine firmware versio...

Page 111: ...ers and Firmware in Huawei Server OS Installation Guide End 5 2 7 Installing a Processor l Do not wear ESD gloves during processor replacement The gloves may catch on pins on the processor socket and damage it l The same model of processors must be used in a server l Before installing a processor clean the surface of the processor the heat sink and the processor carrier If there is residual therma...

Page 112: ...ons of processors Step 10 Install the processor on the carrier 1 Take a processor carrier out of an ESD bag 2 Aligning the notch in one edge of the processor with the protrusion on the processor carrier secure it Ensure that the processor corner with a triangle mark is in the corner of the processor carrier with a notched triangle FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part I...

Page 113: ...e processor is tilted press the tilted part to fasten it Step 11 Apply thermal compound 1 Determine the area on the processor that will be in contact with the heat sink and evenly apply 0 4 ml of thermal compound on the area NOTE When applying thermal compound place the processor carrier on the desktop The thermal compound injector has volume marks The two line five dot s shape and X shape pattern...

Page 114: ...ompound is evenly and fully coated Figure 5 15 Smeared thermal compound layer Step 12 Install the processor carrier to the heat sink 1 Aligning the processor corner with a triangle mark with the corner of the heat sink with a notched triangle buckle the processor carrier on the heat sink FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part Installation Issue 06 2019 08 10 Copyright Hu...

Page 115: ...firmly secured If the processor carrier is not firmly buckled with the heat sink press the processor carrier to secure it Figure 5 17 Checking the assembly Step 13 Install the processor and heat sink 1 Remove the processor socket cover FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part Installation Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 107 ...

Page 116: ...stop the operation and contact Huawei technical support 3 Horizontally holding the processor and heat sink align the notched corner on the heat sink with the notched corner on the processor socket and place the processor and heat sink downwards on the socket along the guide sleeves Keep the processor and heat sink parallel with the mainboard to prevent damage to processor socket pins FusionServer ...

Page 117: ... tighten the two diagonal screws marked 2 in the label in the middle of the heat sink See 2 in Figure 5 20 Figure 5 20 Installing the heat sink Huawei developed heat sink i Use a Phillips screwdriver to tighten the two diagonal screws marked 1 on the label on the heat sink See 1 in Figure 5 21 FusionServer Pro CH121 V5 Compute Node User Guide 5 Optional Part Installation Issue 06 2019 08 10 Copyri...

Page 118: ...Card Step 16 Install the air duct For details see 3 8 Installing the Air Duct Step 17 Install the cover For details see 3 6 Installing the Cover Step 18 Install the compute node For details see 3 4 Installing a CH121 V5 Step 19 Power on the compute node For details see 3 2 Power On Procedure End 5 2 8 Installing a Memory Module Procedure Step 1 Power off the compute node For details see 3 1 Power ...

Page 119: ... PCIe Card Step 8 Take a spare memory module Step 9 Check the positions and installation guidelines of the memory modules For details see 2 3 5 Memory Installation Positions Figure 5 22 Memory slots Step 10 Install the memory module 1 Open the two memory module ejectors on the memory slot Figure 5 23 Opening the memory module ejectors 2 Align the edge connector of the memory module with the alignm...

Page 120: ... Card Step 13 Install the air duct For details see 3 8 Installing the Air Duct Step 14 Install the cover For details see 3 6 Installing the Cover Step 15 Install the compute node For details see 3 4 Installing a CH121 V5 Step 16 Power on the compute node For details see 3 2 Power On Procedure Step 17 Check whether the memory module is replaced successfully 1 Log in to the iBMC WebUI For details se...

Page 121: ...ff Procedure Step 2 Remove the compute node For details see 3 3 Removing a CH121 V5 Step 3 Place the compute node on the ESD workstation Step 4 Remove the cover For details see 3 5 Removing the Cover Step 5 Take the spare part out of its ESD bag Step 6 Determine the position of the TPM Figure 5 25 Position of the TPM Step 7 Install the TPM 1 Insert the TPM vertically into the connector on the main...

Page 122: ...ble TPM 1 Access the BIOS interface For details see Huawei Server Purley Platform BIOS Parameter Reference 2 Select Security 3 Select TPM Operation and press Enter 4 Select Enable 5 Press F10 The system displays Exit Saving changes dialog box is displayed 6 Select Yes The settings are saved 7 Restart the server The TPM settings take effect after the server is restarted End FusionServer Pro CH121 V...

Page 123: ...nd hardware supported Do not use incompatible components Otherwise the server may fail to work properly The technical support and warranty do not cover faults caused by incompatible components FusionServer Pro CH121 V5 Compute Node User Guide 6 Software and Hardware Compatibility Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 115 ...

Page 124: ...on If a fault occurs on a server collect logs for fault diagnosis l Fault diagnosis Fault diagnosis rules and tools help Huawei technical support engineers and maintenance engineers to analyze and rectify faults according to alarms and hardware fault symptoms l Software and firmware upgrade Software and firmware upgrade packages can be downloaded by server model and installed as needed l Preventiv...

Page 125: ...Guide l E9000 Server V100R001 Upgrade Guide l FusionServer iDriver List l FusionServer Tools 2 0 uMate User Guide Upgrading Software or Firmware l Upgrade the iBMC BIOS CPLD or other firmware For details see E9000 Server V100R001 Upgrade Guide Installing or Updating the Driver If the existing driver versions on a server are inconsistent with the driver version mapping install the drivers of the re...

Page 126: ...upper layer network management system NMS Starts resets and performs power control of the compute nodes in the chassis Records and queries logs Manages users including MM910 administrators and compute node iBMC users l KVM over IP The KVM over IP function allows users to remotely monitor and control devices using a local keyboard video and mouse KVM on the client l Virtual media Virtual media is u...

Page 127: ...Huawei proprietary intelligent system for remotely managing a server The iBMC complies with IPMI 2 0 and SNMP standards and supports various functions including KVM redirection text console redirection remote virtual media and hardware monitoring and management The iBMC provides the following features l Multiple management interfaces for system integration The iBMC provides IPMI command line inter...

Page 128: ...system OS and the hardware to interact with the keyboard display and other input output I O devices The BIOS data is stored on the Serial Peripheral Interface SPI flash memory The BIOS performs a power on self test POST initializes CPU and memory checks the I O and boot device and finally boots the OS The BIOS also provides the advanced configuration and power interface ACPI and hot swap The Huawe...

Page 129: ...ollection function helps users determine hardware health status based on collected log information Firmware upgrade function helps users upgrade server firmware Power control function helps users power on power off and restart servers BIOS configuration function helps users perform BIOS configuration for servers BMC configuration function helps users perform BMC configuration for servers HMM confi...

Page 130: ...inux OSs are supported l User friendly interfaces uMate provides a GUI and CLI l Easy operations Users can perform operations as prompted and batch operations are supported FusionServer Pro CH121 V5 Compute Node User Guide 8 Software and Configuration Utilities Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 122 ...

Page 131: ...ving a forklift l Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference Personal Safety l Only personnel certified or authorized by Huawei are allowed to install the hardware l Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures l Do...

Page 132: ...ice Figure 9 2 Conductive objects to be removed Figure 9 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis FusionServer Pro CH121 V5 Compute Node User Guide 9 Safety ...

Page 133: ...uch as the PSUs fan modules drives and the mainboard Handle the equipment with care l Exercise caution when using tools that could cause personal injury l Connect the primary and secondary power cables to different power distribution units PDUs to ensure reliable system operation l Properly ground a device before powering it on Transportation Precautions Improper transportation may damage equipmen...

Page 134: ... one person is permitted to carry Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quarantine of the People s Republic of China AQSIQ l Men ...

Page 135: ...ipment room The heating system reduces indoor humidity and increases ESD l Place unused products into ESD bags to prevent direct contact with humans during transportation and storage l Before products arrive at an ESD area store them in their own packages l Place the product package on a grounded surface before taking out the product l Wear an ESD wrist strap when installing or removing a server c...

Page 136: ...gainst the skin l Use heel straps toe straps or boot straps in standing workplaces Wear the straps on both feet when standing on conductive floors or dissipating floor mats l Use conductive field service tools l Use a portable field service kit with a folding static dissipating work mat FusionServer Pro CH121 V5 Compute Node User Guide 10 ESD Issue 06 2019 08 10 Copyright Huawei Technologies Co Lt...

Page 137: ...n memory controller and six memory channels l Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor l Two UPI buses between processors providing up to 10 4GT s transmission per channel l Up to 28 cores 2 7 GHz l Max 3 8 GHz four cores l Min 1 375 MB L3 cache per core l Max 205 W TDP NOTE The preceding information is for reference only Use the Intelligent Computing Compatibility C...

Page 138: ...Compatibility Checker to obtain information about the specific RAID controller cards supported The RAID controller card supports RAID configuration RAID level migration and drive roaming The RAID controller card does not occupy a standard PCIe slot For details about the RAID controller card see Huawei V5 Server RAID Controller Card User Guide NOTE If the BIOS is in legacy mode 4Kn drives 4 KB sect...

Page 139: ...ces NOTE The preceding information is for reference only Use the Intelligent Computing Compatibility Checker to obtain specific information Ports Supports a variety of ports l Ports on the front panel Two USB 3 0 ports l Built in port One USB 3 0 port NOTE The maximum dimensions H x W x D of the built in USB device are 33 9 mm x 14 5 mm x 7 12 mm 1 33 in x 0 57 in x 0 28 in Video card An SM750 vid...

Page 140: ...ltitude 3050 m 10006 44 ft When the server configuration complies with ASHRAE Class A2 standards and the altitude is above 900 m 2952 76 ft the highest operating temperature decreases by 1 C 1 8 F for every increase of 300 m 984 24 ft When the server configuration complies with ASHRAE Class A3 standards and the altitude is above 900 m 2952 76 ft the highest operating temperature decreases by 1 C 1...

Page 141: ...hysical Specifications Table 11 3 Physical specifications Category Description Dimensions H x W x D 60 46 mm x 210 mm x 537 2 mm 2 38 in x 8 27 in x 21 15 in Weight in full configuration l Net weight 6 5 kg 14 33 lb l Packing materials 2 3 kg 5 07 lb Power consumption The power consumption parameters vary with the configuration Use the Huawei Server Power Calculator to obtain specific information ...

Page 142: ...dress Scenarios Query the IP address of the iBMC management network port The following describes how to query the iBMC IP address on the BIOS You can use any of the following methods to query the IP address of the iBMC management network port l BIOS l iBMC WebUI For details see FusionServer Pro E9000 Server iBMC User Guide l iBMC CLI Run the ipmcget d ipinfo command For details see FusionServer Pr...

Page 143: ...automatically logged out of the WebUI l The system locks a user account if the user enters incorrect passwords for consecutive five times The user account is automatically unlocked five minutes later The system administrator can also unlock a user account using the command line l For security purposes change the initial password after the first login and change your password periodically Procedure...

Page 144: ... to 44 0 Windows Server 2012 64 bit Internet Explorer 10 0 11 0 JRE 1 7 U45 JRE 1 8 U45 JRE 1 8 U144 Mozilla Firefox 39 0 to 54 0 Google Chrome 21 0 to 44 0 RHEL 6 0 64 bit Mozilla Firefox 39 0 to 54 0 JRE 1 7 U45 JRE 1 8 U45 JRE 1 8 U144 MAC X v10 7 Safari 8 0 JRE 1 7 U45 JRE 1 8 U45 JRE 1 8 U144 Mozilla Firefox 39 0 to 54 0 Step 2 Connect the PC to the iBMC management network port using a networ...

Page 145: ...nel or reduce the Java security level This operation however poses security risks Exercise caution when performing this operation Figure 12 1 iBMC UI for login Step 5 Log in to the iBMC WebUI l Log in as a local user a Select the language to be used b Enter the user name and password NOTE n The system provides a default user of the administrator group The default user name is Administrator and the...

Page 146: ...MC provides only the access function for LDAP users a Select the language to be used b Enter the LDAP user name and password NOTE n If an LDAP user name is entered in User Name Domain can be Automatic matching or a specified domain n If LDAP user name Domain name is entered Domain must be Automatic matching n In versions earlier than iBMC V294 the maximum password length for an LDAP user is 20 cha...

Page 147: ...time l The WebUI of the standby MM910 displayed as This is the standby MM does not display the component installation status After logging in to the WebUI of the standby MM910 you can view monitoring information about the active MM910 set the DHCP and static IP addresses and set and query the thresholds and hysteresis of the sensors of the standby MM910 To perform other operations log in to the We...

Page 148: ... CX911 CX912 CX913 as the management port of the management module MGMT port on the MM910 panel For the MM910 U54 2 25 or earlier the management port is provided by the switch module by default For the MM910 U54 2 26 or later the management port is provided by the MM910 by default For details about how to query the MM910 version see MM910 Management Module V100R001 User Guide You can run the outpo...

Page 149: ...M910 If the STACK port is used to stack the MGMT port in another chassis connect the local PC to an idle STACK port on an active MM910 in a chassis cascaded with the E9000 chassis If the MGMT port on the active MM910 is already connected with a network cable do not remove the network cable from the MGMT port Otherwise an active standby switchover of the MM910s will be triggered which may cause net...

Page 150: ... Windows 7 Step 5 Choose Connections and click LAN Settings The Local Area Network LAN Settings dialog box is displayed Step 6 In the Proxy server group box deselect Use a proxy server for your LAN Step 7 Click OK The Local Area Network LAN Settings dialog box is closed Step 8 Click OK The Internet Options dialog box is closed Step 9 Restart Internet Explorer enter https MM910 floating IP address ...

Page 151: ... and click Sites 4 In the Trusted sites dialog box click Add to add the IP address to the trusted site list 5 Click Close 6 Refresh the web page of the added site 7 In the status bar of Internet Explorer check that the added site is in the Trusted sites zone Step 11 Click Continue to this website not recommended The HMM Web login page is displayed Step 12 Set the login parameters NOTE The login pa...

Page 152: ...ters l Select MM for Collected from l Select One click full collection for Collected content Step 3 Click Start Collection Figure 12 7 Collecting Information Step 4 In the displayed dialog box click Save and save the log file to the local PC Step 5 Decompress the one_touch_info_all tar gz file The log information is in the bladeN folder NOTE N indicates the compute node slot number which ranges fr...

Page 153: ... Please log in with SMM account and password user name Step 3 Enter the user name and password NOTE The default user name of compute nodes is Administrator and the default password is Admin 9000 The CLI for selecting a slot is displayed Log in Success please input the SOL Blade1 Blade16 1 16 Blade1A Blade16A 17 32 Swi1 Swi4 33 36 and COM n press Ctrl R to return Blade1 Blade16 1 16 Blade1A Blade16...

Page 154: ... a compute node or switch module using SOL The local KVM of the MM910 has the following limitations l The CLI does not provide the text editor l You can access the system serial port of a compute node over SOL of the KVM NOTE If you have accessed the CLI of the primary MM backup MM or SOL screen shown in Figure 12 8 and the login has not timed out you do not need to enter the user name and passwor...

Page 155: ...ating System of a Compute Node Scenarios Log in to the operating system of a compute node using the local KVM Procedure Step 1 Connect the KVM to the MM910 1 Connect the mouse and keyboard to the two USB ports on the MM910 2 Use a VGA cable to connect the KVM monitor to the VGA port on the MM910 The main screen of the KVM is displayed FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Ope...

Page 156: ... drive to a compute node using the local KVM Procedure Step 1 Connect the KVM to the MM910 1 Connect the mouse and keyboard to the two USB ports on the MM910 2 Use a VGA cable to connect the KVM monitor to the VGA port on the MM910 The main screen of the KVM is displayed FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd ...

Page 157: ... that the DVD drive is mounted to the compute node l indicates that the DVD drive is open l indicates that data is being read End 12 6 4 Logging In to a Compute Node or a Switch Module over SOL Scenarios Use the local KVM to log in to a compute node or switch module over SOL FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co ...

Page 158: ...dule over SOL 1 Press CTRL S on the KVM home page The following information is displayed Welcome to SMM SOL Server Please log in with SMM account and password user name NOTE You can press Ctrl Shift Alt to return to the previous screen or press CTRL R to return to the KVM main screen 2 Type the MM910 user name and password and press Enter The following information is displayed FusionServer Pro CH1...

Page 159: ...our choice 34 1 BMCcom 2 fabriccom 3 baseccom 4 FCcom COM 1 4 4 Enter the number of the serial port to be connected for example type 1 and press Enter The serial port screen is displayed 5 Enter the user name and password for connecting to the serial port You can query information and configure data on this interface End 12 7 Logging In to the Desktop of a Server 12 7 1 Using the Remote Virtual Co...

Page 160: ...he operations performed by the other user l HTML5 Integrated Remote Console Private allows only one local user or VNC user to access and perform operations on the server through the iBMC l HTML5 Integrated Remote Console Shared allows two local users or up to five VNC users to simultaneously access and perform operations on the server through the iBMC Each user can view the operations performed by...

Page 161: ...Figure 12 13 Remote console Java FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 153 ...

Page 162: ...MM910 WebUI For details see 12 3 Logging In to the MM910 WebUI Step 2 Click KVM via MM The Security Warning dialog box is displayed Step 3 Click Yes The Warning Security dialog box is displayed Step 4 Click Yes The remote KVM page is displayed FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 154 ...

Page 163: ...IRC at Independent Remote Console 12 7 2 1 Windows The following Windows versions are supported l Windows 7 32 bit or 64 bit l Windows 8 32 bit or 64 bit l Windows 10 32 bit or 64 bit l Windows Server 2008 R2 32 bit or 64 bit l Windows Server 2012 64 bit Procedure Step 1 Configure an IP address for the client PC to enable communication between the client and the iBMC The IP address configured and ...

Page 164: ...ber l When the port number is the default port number 443 the port number can be left blank Step 4 Select a login mode l Shared Mode allows two users to access and manage a server at the same time Each user can view the operations performed by the other user l Private Mode allows only one user to access and manage a server at a time Step 5 Click Connect A security warning is displayed Figure 12 17...

Page 165: ...ep 1 Configure an IP address for the client PC to enable communication between the client and the iBMC The IP address configured and the iBMC management network port IP address must be on the same network segment Step 2 Open the console and set the folder where the IRC is stored as the working folder Step 3 Run the chmod 777 KVM sh command to set the permission for the Independent Remote Console S...

Page 166: ... name address Port number l When the port number is the default port number 443 the port number can be left blank Step 6 Select a login mode l Shared Mode allows two users to access and manage a server at the same time Each user can view the operations performed by the other user l Private Mode allows only one user to access and manage a server at a time Step 7 Click Connect A security warning is ...

Page 167: ...gure an IP address for the client PC to enable communication between the client and the iBMC The IP address configured and the iBMC management network port IP address must be on the same network segment Step 2 Open the console and set the folder where the IRC is stored as the working folder Step 3 Run the chmod 777 KVM sh command to set the permission for the Independent Remote Console Step 4 Open...

Page 168: ... name address Port number l When the port number is the default port number 443 the port number can be left blank Step 6 Select a login mode l Shared Mode allows two users to access and manage a server at the same time Each user can view the operations performed by the other user l Private Mode allows only one user to access and manage a server at a time Step 7 Click Connect A security warning is ...

Page 169: ...I Using PuTTY over a Network Port Scenarios Use PuTTY to access a server over a local area network LAN NOTE l You can obtain the PuTTY software from the chiark home page l You are advised to use PuTTY of the latest version PuTTY of an earlier version may cause login failures Procedure Step 1 Set an IP address and subnet mask or add route information for the PC to communicate with the server Fusion...

Page 170: ...ain the default value 22 l Connection type Retain the default value SSH Step 5 In the navigation tree choose Session Step 6 Select SSH under Connection type Figure 12 25 PuTTY Configuration Step 7 Set Close window on exit to Only on clean exit NOTE Set Saved Sessions and click Save You can double click the saved record in Saved Sessions to log in to the server next time Step 8 Click Open FusionSer...

Page 171: ...acy mode does not support this setting l Use Intelligent Computing Compatibility Checker to obtain information about the operating systems supported by the VMD function l After the VMD function is enabled and the latest VMD driver is installed the server supports Surprise hot plug of NVMe drives 12 9 1 Enabling VMD Procedure Step 1 Access the BIOS interface Step 2 Choose Advanced Step 3 Select Soc...

Page 172: ... overwrite data on the storage device The following describes how to clear the data on one HDD SSD as an example This operation is for reference only You can also use other methods to clear data from storage media The cleared data cannot be restored Exercise caution when performing this operation Procedure NOTE Before performing this operation check that l The storage device is not in a RAID array...

Page 173: ...the system drive l Do not directly clear system drive data Before clearing system drive data clear data from other storage media Figure 12 27 Querying drive information Step 5 Write all 0s to the drive to be cleared Command badblocks swft 0 Drive letter Example badblocks swft 0 dev sdb Figure 12 28 Clearing data example FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Operations Issue 0...

Page 174: ...f the command fails to execute contact technical support Step 6 Remove the drive NOTE After the data is cleared do not restart or reinstall the server Otherwise the system will reload data to the drives during the startup of the server End FusionServer Pro CH121 V5 Compute Node User Guide 12 Common Operations Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 166 ...

Page 175: ...nity Learn more about servers and communicate with experts at l HUAWEI Server Information Service Platform for specific server product documentation l iKnow for Q A about products l Huawei Enterprise Support Community Server for learning and discussion News For notices about product life cycles warnings and updates visit Support Bulletins Product Bulletins Cases To learn server applications visit ...

Page 176: ...umentation Server user guide which provides information about the structure specifications and installation of the server Visit Intelligent Servers select a product model and view the Documentation tab page Intelligent Computing Compatibility Checker A tool used to query the OSs parts and peripherals compatible with a server Intelligent Computing Compatibility Checker Maintenance Information Inqui...

Page 177: ...r routine maintenance Tool Server Model and Software Version Description FusionServer Tools uMate For details see FusionServer Tools 2 0 uMate User Guide uMate performs routine maintenance tasks for servers The tasks include preventive maintenance batch firmware upgrades and batch power control Download link FusionServer Tools FusionServer Tools InfoCollect For details see FusionServer Tools 2 0 I...

Page 178: ... example Table B 1 SN description Callout No Description 1 SN ID two characters which is 21 2 Material identification code 8 characters that is the processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors FusionServer Pro CH121 V5 Compute Node User Guide B Appendix Issue 06 2019 08 10 Copyright Huawei Technologies Co Ltd 170 ...

Page 179: ...roduct name B 2 RAS Features Table B 2 describes the reliability availability and serviceability RAS features supported by the server You can configure these features for better RAS For details about how to configure RAS features see Huawei Server Purley Platform BIOS Parameter Reference Table B 2 RAS features Module Feature Description CPU Corrected Machine Check Interrupt Corrects error triggere...

Page 180: ...ncy check CRC protection for UPI packets to improve system reliability System Core Disable for Fault Resilient Boot FRB Isolates a faulty CPU core during startup to improve system reliability and availability Corrupt Data Containment Mode Identifies the memory storage unit that contains corrupted data to minimize the impact on the running programs and improve system reliability Socket disable for ...

Page 181: ...ite data to facilitate fault analysis and locating and improve system serviceability BIOS Abstraction Layer for Error Handling The BIOS processes errors and reports the error information to the OS and the server in compliance with specifications to improve system serviceability BIOS based Predictive Failure Analysis PFA The BIOS provides physical unit information for DIMM errors and the OS traces ...

Reviews: