The message
There is a problem with this website's security certificate
is displayed.
NOTE
You can query or configure the MM910 floating IP address by using:
l
Chassis intelligent display. For details, see
E9000 Chassis Intelligent Display V100R001
.
l
MM910 WebUI. For details, see "Configuring the MM910 IP Address" in
l
floatip
command on the MM910 CLI. For details, see
MM910 Management Module V100R001
Step 10
(Optional) Add the IP address of the MM910 to the
Trusted sites
zone.
NOTE
By default, the Internet Explorer enhanced security configuration is enabled on the Windows Server
OSs. You need to add the IP address of the MM910 to the
Trusted sites
zone.
1.
On the menu bar of Internet Explorer, choose
Tools
>
Internet Options
.
The
Internet Options
dialog box is displayed.
2.
Click the
Security
tab.
3.
Click
Trusted sites
and click
Sites
.
4.
In the
Trusted sites
dialog box, click
Add
to add the IP address to the trusted site list.
5.
Click
Close
.
6.
Refresh the web page of the added site.
7.
In the status bar of Internet Explorer, check that the added site is in the
Trusted sites
zone.
Step 11
Click
Continue to this website (not recommended)
.
The
HMM Web
login page is displayed.
Step 12
Set the login parameters.
NOTE
The login page varies slightly with the HMM software version.
l
Language
: Select the language to be used.
l
User name
: Enter the user name. The default user name is
root
.
l
Enter the user password. The default password is
Huawei12#$
.
If
User must change password at next login
is selected during user creation on the
LDAP server, logins will fail. The option needs to be deselected on the LDAP server.
l
Login To
: Select
This Machine
.
Select
LDAP
if the system manages domain users by using an active directory (AD)
server.
Figure 12-5
HMM Web login page (the MM910 software version is
V603
)
FusionServer Pro CH121 V5 Compute Node
User Guide
12 Common Operations
Issue 06 (2019-08-10)
Copyright © Huawei Technologies Co., Ltd.
143