Figure 26 Four DL380p Gen8 Storage CLIMs, Four M8381-25 SAS Disk Enclosure
Configuration
This table lists the Storage CLIM, LUN, and bay identification for the factory-default system disk
locations in the configuration of four DL380p Gen8 Storage CLIMs and four M8381-25 SAS disk
enclosures. In this case, $SYSTEM, $DSMSCM, $AUDIT, and OSS are configured as mirrored
SAS disk volumes:
Mirror Disk
Location in Mirror
SAS Enclosure
Primary
Disk Bay in
Primary
SAS
Enclosure
Mirror
LUN
Primay
LUN
Mirror-Backup
CLIM
Mirror
CLIM
Backup
CLIM
Primary
CLIM
Disk
Volume
Name
1
1
101
101
100.2.5.3.3
100.2.5.4.3
100.2.5.4.1
100.2.5.3.1
$SYSTEM
2
2
102
102
100.2.5.3.3
100.2.5.4.3
100.2.5.4.1
100.2.5.3.1
$DSMSCM
3
3
103
103
100.2.5.3.3
100.2.5.4.3
100.2.5.4.1
100.2.5.3.1
$AUDIT
4
4
104
104
100.2.5.3.3
100.2.5.4.3
100.2.5.4.1
100.2.5.3.1
$OSS
Four DL380p Gen8 Storage CLIMs, Eight M8381-25 SAS Disk Enclosures
This illustration shows example cable connections for the four DL380p Gen8 Storage CLIM, eight
M8381-25 SAS disk enclosures configuration. This configuration uses two SAS ports in slots 2
and 3 of each DL380p Gen8 Storage CLIM to connect to the P1 ports on each SAS disk enclosure
I/O module.
82