Two DL380p Gen8 Storage CLIMs, Two M8381-25 SAS Disk Enclosures
This illustration shows example cable connections between the two DL380p Gen8 Storage CLIM,
two M8381-25 SAS disk enclosure configuration.
Figure 24 Two DL380p Gen8 Storage CLIMs, Two M8381-25 SAS Disk Enclosure
Configuration
This table lists the Storage CLIM, LUN, and bay identification for the factory-default system disk
locations in the configuration of two DL380p Gen8 Storage CLIMs and two M8381-25 SAS disk
enclosures. In this case, $SYSTEM, $DSMSCM, $AUDIT, and OSS are configured as mirrored
SAS disk volumes:
Mirror Disk
Location in Mirror
SAS Enclosure
Primary
Disk Bay in
Primary
SAS
Enclosure
Mirror
LUN
Primay
LUN
Mirror-Backup
CLIM
Mirror
CLIM
Backup
CLIM
Primary
CLIM
Disk
Volume
Name
1
1
201
101
100.2.5.3.1
100.2.5.3.3
100.2.5.3.3
100.2.5.3.1
$SYSTEM
2
2
202
102
100.2.5.3.1
100.2.5.3.3
100.2.5.3.3
100.2.5.3.1
$DSMSCM
3
3
203
103
100.2.5.3.1
100.2.5.3.3
100.2.5.3.3
100.2.5.3.1
$AUDIT
4
4
204
104
100.2.5.3.1
100.2.5.3.3
100.2.5.3.3
100.2.5.3.1
$OSS
80
System Configuration Guidelines for NS2100 Systems