Event
code
Message and description
Details and solution
4097
Drive port configured to NPIV but failed to
negotiate with Fibre Channel switch.
1.
Verify that the FC switch supports NPIV
and that this option is enabled for the
port connected to the tape drive.
2.
If the problem persists, disconnect and
reconnect the cable after changing the
FC switch NPIV configuration.
3.
If your infrastructure cannot support
NPIV, disable basic control path failover.
4098
System time synchronization through SNTP
failed.
1.
Verify that the SNTP server address in
the
Configuration > System > Date and
Time Format
screen is valid.
2.
Ensure that the SNTP server is
reachable from the library network and
not blocked by a firewall.
4099
An unexpected reset of robotics has been
detected.
Verify that the spooling cable is fully seated
in the base module and correctly connected
to the robotic assembly.
4100
Drive with FIPS Secure Mode enabled has
been hot removed while in active status as
data transfer device.
LTO-6 tape drives with FIPS Secure Mode
enabled must be powered off before
removing them from the library. For
additional information and instructions, see
Disabling Secure Mode for an LTO-6 tape
drive
on page 83.
4101
The drive configuration failed. FIPS Secure
Mode is not supported.
1.
Replace the drive with an LTO-6 or later
generation drive or disable FIPS Secure
Mode for this partition.
2.
If the drive is an LTO-6 or later
generation drive, update the drive
firmware to the latest version.
4102
The drive configuration failed due to an error
during FIPS Secure Mode specific
operation.
Retry the operation. If the problem persists,
verify that the drive is running the latest
released firmware version and that the
partition FIPS Support Mode settings are
correct.
Table Continued
Event codes
229