Event
code
Message text and description
Details and solution
2053
An open top cover was detected and as
a result the system was taken offline.
1.
Ensure that the top cover is inserted
completely and properly locked.
2.
Verify that no items are sitting on top of the
library.
3.
Do not remove the top cover while the library
is powered on.
2054
An open bottom cover was detected and
as a result the system was taken offline.
1.
Ensure that the bottom cover is inserted
completely and properly locked.
2.
Do not remove the bottom cover while the
library is powered on.
2055
An open unit lock was detected and as a
result the system was taken offline.
1.
Ensure that all alignment mechanisms
between modules are properly locked.
2.
Do not open the alignment mechanism locks
while the library is operating and the robot is
moving.
2056
Initialization failure due to picker push
pull positioning error.
Check for obstructions in the horizontal pathway
of the robotics assembly, such as a cartridge
sticking out or a cable impeding movement of
the robotics assembly.
2057
Robotics shipping lock in incorrect
position.
1.
Ensure that both the top and bottom covers
are installed and then reboot the library.
2.
If this error occurs after the reboot, unlock
the shipping lock.
2058
Maximum temperature for Drive Power
Board 1 has been exceeded. Shutting
down the system.
Each module has two drive power boards,
which are located under the chassis fan. The
left drive power board provides power for the
upper three half-height tape drive bays in the
module. The right drive power board provides
power for the lower three half-height tape drive
bays in the module. See the event details to
determine which drive power board failed.
• Ensure that all chassis fans are installed and
operational.
• Verify that all empty tape drive bays have
covers installed.
2059
Maximum temperature for Drive Power
Board 2 has been exceeded. Shutting
down the system.
Table Continued
Event codes