![HP StoreEver MSL3040 User'S And Service Manual Download Page 100](http://html.mh-extra.com/html/hp/storeever-msl3040/storeever-msl3040_users-and-service-manual_2175305100.webp)
Procedure
1.
Navigate to the
Maintenance > Library Tests > Position Test
screen.
2.
Select the source and destination element addresses and number of cycles.
3.
Click
Start
.
Performing the wellness test
The wellness test exercises basic library functionality. At the end of the test, cartridges will be in different
storage slots.
CAUTION:
The test can move cartridges between partitions. Especially if the library is configured for
encryption, ensure that all cartridges are returned to their original partitions after the test.
Prerequisites
• At least one drive must be empty.
• At least one cartridge that is compatible with the empty drive must be in a magazine slot or mailslot.
If moving a cartridge to or from a tape drive, the cartridge must be compatible with the generation of
the tape drive.
• One of the selected element locations must be empty and one of the selected element locations must
be full.
• Each library module must have at least one cartridge installed.
• All backup operations are stopped.
The test takes the library offline to hosts for the duration of the test.
Procedure
1.
Navigate to the
Maintenance > Library Tests > Wellness Test
screen.
2.
Click
Start Test
.
Performing the robotic test
The robotic test performs a full inventory and exercises all robotic assembly movements and sensors.
Procedure
1.
Navigate to the
Maintenance > Library Tests > Robotic Test
screen.
2.
Click
Start Test
.
100
Performing the wellness test