3.
Follow the instructions in the readme file to load the NVRAM configuration onto each FCA.
•
If you have a blade server other than a ProLiant blade server:
1.
Download the supported FCA BIOS update, available on
2.
Unzip the file.
3.
Follow the instructions in the readme file to load the NVRAM configuration onto each FCA.
Setting the multipathing policy
You can set the multipathing policy for each logical unit number (LUN) or logical drive on the storage
area network (SAN) to one of the following:
•
Most recently used (MRU)
•
Fixed
•
Preferred
ESX 2.5.x commands
The
# vmkmultipath –s vmhba0:0:1 –p mru
command sets
vmhba0:0:1
with an MRU
multipathing policy for all LUNs on the SAN.
The
# vmkmultipath -s vmhba1:0:1 -p fixed
command sets
vmhba1:0:1
with a Fixed
multipathing policy.
The
# vmkmultipath -s vmhba1:0:1 -r vmhba2:0:1 -e vmhba2:0:1
command sets and
enables
vmhba2:0:1
with a Preferred multipathing policy.
ESX 3.x commands
The
# esxcfg-mpath --policy=mru --lun=vmhba0:0:1
command sets
vmhba0:0:1
with
an MRU multipathing policy.
The
# esxcfg-mpath --policy=fixed --lun=vmhba0:0:1
command sets
vmhba1:0:1
with a Fixed multipathing policy.
The
# esxcfg-mpath --preferred --path=vmhba2:0:1 --lun=vmhba2:0:1
command
sets
vmhba2:0:1
with a Preferred multipathing policy.
NOTE:
Each LUN can be accessed through both EVA storage controllers at the same time; however, each
LUN path is optimized through one controller. To optimize performance, if the LUN multipathing
policy is Fixed, all servers must use a path to the same controller.
You can also set the multipathing policy from the VMware Management User Interface (MUI) by
clicking the
Failover Paths
tab in the Storage Management section and then selecting
Edit… link
for
each LUN whose policy you want to modify.
Specifying DiskMaxLUN
The
DiskMaxLUN
setting specifies the highest-numbered LUN that can be scanned by the ESX server.
•
For ESX 2.5.x, the default value is 8. If more than eight LUNs are presented, you must change the
setting to an appropriate value. To set
DiskMaxLUN
, select
Options> Advanced Settings
in the
MUI, and then enter the highest-numbered LUN.
Configuring non-Windows application servers
76
Summary of Contents for StorageWorks 4400
Page 16: ...Figure 4 Installation checklist cont d About this guide 16 ...
Page 20: ...Review and confirm your plans 20 ...
Page 24: ...Remove product from packaging 24 ...
Page 36: ...Connect cables and power cords 36 ...
Page 48: ...Configuring management servers using HP SmartStart EVA Storage 48 ...
Page 50: ...Configuring application servers for Windows using HP SmartStart EVA Storage 50 ...
Page 78: ...Configuring non Windows application servers 78 ...