POST Error Messages
C-38
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
1600 Series POST Error Messages
Table C-12: 1600 Series POST Error Messages
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1610- Temperature
violation detected. -
Waiting 5 Minutes for
System to Cool.
None
The ambient system
temperature has
exceeded acceptable
levels.
Room temperature is too
high; lower the room
temperature.
1610- Temperature
violation detected.
Waiting for system
to cool
2 short
The ambient system
temperature is too hot.
Check fan in system
environment.
1610-I/O Board
Temperature Violation
detected
None
An overheating condition
has occurred on the I/O
board.
Turn off system and let it cool
down. Be sure that the
system fans are functional
and that the rack allows
adequate ventilation.
Also, be sure that the ambient
temperature is within the
operating parameters of the
system. Check your server-
specific user documentation
for the temperature
requirements of your server.
1611-Fan
X
not
present
2 short
Fan is not installed or is
not seated.
Reseat or install a fan in
position
X
.
1611-CPU Fan failure
detected
None
Required fan not
spinning.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
continued