POST Error Messages
C-14
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
200 Series POST Error Messages
Table C-4: 200 Series POST Error Messages
Error Code
Audible
Beeps
Probable Source of
Problem
Action
201-Memory Error
None
RAM failure detected.
Run Diagnostics. Replace
failed assembly as indicated.
201-Memory Error
The memory test
performed during
startup failed.
Removing and
replacing memory
modules can isolate
the faulty memory.
Also verify that the
memory modules are
installed correctly.
None
RAM failure detected.
Run Diagnostics. Replace
failed assembly as instructed.
202-Memory Type
Mismatch
2 short
An incompatible memory
module is installed in the
system.
Compare part numbers from
installed memory modules
with those listed in your
server-specific user
documentation.
If not listed, the memory
modules are incompatible and
should be replaced or
removed.
203-Memory Address
Error
None
RAM failure detected.
Run Diagnostics. Replace
failed assembly as indicated.
205-Cache Memory
error
2 short
A memory module is
malfunctioning.
Run Diagnostics. Replace or
remove malfunctioning
memory module as indicated.
continued