ADU Error Messages
D-20
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Swapped cables or
Configuration error detected. A
drive rearrangement was
attempted while an expand
operation was running. This is
an unsupported operation.
SOLUTION: Power down
system then move drives back
to their original location. Power
on system and wait for the
expand operation to complete
before attempting a drive
rearrangement.
One or more drive locations
were changed while an
expand operation was in
progress.
1. Power down the server.
2. Place the drives in their
original locations.
3. Restart the server, and
then complete the expand
operation.
4. Move the drives to their
new locations after the
expand operation is
completed.
Swapped cables or
Configuration error detected.
An unsupported drive
arrangement was attempted.
SOLUTION: Power down
system then move drives back
to their original location.
One or more physical drives
were moved, causing a
configuration that is not
supported.
Move all drives to their original
locations, and then refer to
your server-specific user
documentation for supported
configurations.
Swapped cables or
Configuration error detected.
The cables appear to be
interchanged.
SOLUTION: Power down
system then move the drives
or cables back to their original
location.
ADU has detected a change in
the cable configuration.
One or more cables may be
connected to the incorrect bus.
-Or-
One or more drives have been
moved to new locations.
Refer to your server-specific
user documentation for
supported configurations and
cabling guidelines.
Restore to the original
configuration.
continued