POST Error Messages
C-54
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1753-Slot z Drive
Array – Array
Controller Maximum
Operating
Temperature
Exceeded During
Previous Power Up.
None
Controller is overheating.
Be sure that there is adequate
system cooling and sufficient
airflow across controller.
1754-Slot z Drive
Array - RAID ADG
drive(s) configured
but ADG Enabler
Module is detached or
defective. Please
check for detached
ADG Enabler Module.
Array Accelerator is
temporarily disabled.
None
RAID ADG drive(s)
configured but ADG
enabler module is
detached or defective.
Replace or reseat ADG
enabler module.
1755-Slot z Drive
Array - ADG Enabler
Module appears to be
Defective. Please
replace ADG Enabler
Module.
None
ADG enabler module is
loose or defective.
Replace or reseat ADG
enabler module.
Smart Array 3100ES
Controller paired with
4250ES controller, or not
fully seated in PCI slot.
In a redundant controller
configuration, both controllers
must be the same model.
Replace one of the controllers
so they are both the same
model.
1756- Redundant
Controllers are Not
the Same Model
None
There is a defective
system board or a
controller that is not fully
seated in the PCI slot.
1. Reseat the controllers.
2. Replace the system
board.
continued