POST Error Messages
C-66
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1789-Slot
X
Drive
Array SCSI Drive(s)
Not Responding.
Check cables or
replace the following
SCSI
drives:
SCSI Port
Y
:
SCSI ID
Z
Select F1 to continue
– drive array will
remain disabled.
Select F2 to failed
drives that are not
responding – Interim
Recovery Mode will
be enabled if
configured for fault
tolerance.
None
Drives that were working
when the system was last
used are now missing or
are not starting up.
Possible drive problem or
loose SCSI cable.
1. Power down the system,
check cable connections,
and be sure that all
drives are fully seated in
their drive bays.
2. Power cycle any external
SCSI enclosures while
the system is off.
3. Power on the server to
see if problem still exists.
4. If configured for fault-
tolerant operation and the
RAID level can sustain
failure of all indicated
drive(s), press the
F2
key
to fail the drive(s) that are
not responding and
replace with good
drive(s) immediately.
5. Otherwise, press the
F1
key to start the system
with all logical drives on
the controller disabled.
Be sure that system is always
powered up and down
correctly.
•
When powering up the
system, all external
storage systems must be
turned on before server.
•
When powering down the
system, the server must
be powered down before
external storage systems.
continued