POST Error Messages
HP Servers Troubleshooting Guide
C-67
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1790-Disk
X
Configuration Error
None
Hard drive error or wrong
drive type detected.
Run the server setup utility
and Diagnostics and correct.
Replace failed assembly as
indicated.
1790-Disk
X
Configuration Error
None
Hard drive error or wrong
drive type detected.
Run the server setup utility
and Diagnostics and correct.
Replace failed assembly as
indicated.
1791-Disk 1 Error
None
Hard drive error or wrong
drive type detected.
Run the server setup utility
and Diagnostics and correct.
Replace failed assembly as
indicated.
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will automatically
be written to drive
array.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
array accelerator
memory. Power was then
restored within several
days, and the data in the
array accelerator was
flushed to the drive array.
No action necessary; no data
has been lost. Perform orderly
system shutdowns to avoid
data remaining in the array
accelerator.
1792-Secondary Disk
Controller Failure
None
Part of the IDE drive
electronics has failed.
Run Diagnostics and replace
failed assembly as indicated.
1793-Drive Array –
Array Accelerator
Battery Depleted –
Data Lost.
(Error message 1794
also displays.)
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
array accelerator
memory.
Array accelerator
batteries failed. Data in
array accelerator has
been lost.
Power was not restored within
enough time. Perform orderly
system shutdowns to avoid
data remaining in the array
accelerator.
continued