Hardware options installation 112
20.
Do one of the following:
o
For tower models, install the tower bezel (on page
31
).
o
For rack models, install the security bezel ("
Security bezel option
" on page
48
).
Power supply options
Hot-plug power supply module
CAUTION:
All power supplies installed in the server must have the same output power capacity.
Verify that all power supplies have the same part number and label color. The system becomes
unstable and may shut down when it detects mismatched power supplies.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To install the component:
1.
Access the product rear panel.
2.
Remove the blank.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.