Hardware options installation 93
Online spare population guidelines
For Online Spare memory mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines (on page
92
).
•
Each channel must have a valid online spare configuration.
•
Each channel can have a different valid online spare configuration.
•
Each populated channel must have a spare rank. A single dual-rank DIMM is not a valid configuration.
Mirrored Memory population guidelines
For Mirrored Memory mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines (on page
92
).
•
Always install DIMMs in channels 1 and 2 for each installed processor.
•
Do not install DIMMs in channel 3 for any processor.
•
DIMMs installed on channel 1 and channel 2 of an installed processor must be identical.
•
In multi-processor configurations, each processor must have a valid Mirrored Memory configuration.
•
In multi-processor configurations, each processor may have a different valid Mirrored Memory
configuration.
Installing a DIMM
CAUTION:
To avoid damage to the hard drives, memory, and other system components, the air
baffle, drive blanks, and access panel must be installed when the server is powered up.
To install the component:
1.
Do one of the following:
o
For tower models, open and remove the tower bezel ("
Remove the tower bezel
" on page
30
).
o
For rack models, if installed, remove the security bezel ("
Remove the security bezel (optional)
" on
page
30
).
2.
Power down the server (on page
29
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
33
).
5.
Remove the access panel (on page
31
).
6.
Remove the air baffle (on page
33
).
7.
Open the DIMM slot latches.
Summary of Contents for ProLiant ML350 Gen9
Page 21: ...Component identification 21 SFF drives o Tower orientation o Rack orientation LFF drives ...
Page 40: ...Operations 40 o LFF model Use a flathead screwdriver to remove the blank from the box ...
Page 122: ...Cabling 122 LFF media cage data cabling Optical device cabling SFF configuration ...
Page 126: ...Cabling 126 HP Smart Storage Battery cabling Power supply backplane cabling GPU power cabling ...
Page 128: ...Cabling 128 Embedded SATA cabling LFF configuration SFF configuration ...
Page 131: ...Cabling 131 o SFF configuration o LFF configuration ...
Page 162: ...Support and other resources 162 ...
Page 163: ...Support and other resources 163 ...