Software and configuration utilities 143
Updating firmware or System ROM
Multiple methods exist to update the firmware or System ROM:
•
HP Service Pack for ProLiant (on page
137
)
•
FWUPDATE utility (on page
143
)
•
FWUpdate command from within the Embedded UEFI shell (on page
143
)
•
Firmware Update application in System Utilities (on page
144
)
•
Online Flash components (on page
144
)
Product entitlement is required to perform updates. For more information, see "Access to HP Support
Materials (on page
142
)."
FWUPDATE utility
The FWUPDATE utility enables you to upgrade the system firmware (BIOS).
To use the utility to upgrade the firmware:
1.
Download the FWUPDATE flash component from the HP website (
http://www.hp.com/go/hpsc
).
2.
Save the FWUPDATE flash components to a USB key.
3.
Set the boot order so the USB key will boot first using one of the following options:
o
Configure the boot order so the USB key is the first bootable device.
o
Press
F11
(Boot Menu) when prompted during system boot to access the
One-Time Boot Menu
. This
menu allows you to select the boot device for a specific boot and does not modify the boot order
configuration settings.
4.
Insert the USB key into an available USB port.
5.
Boot the system.
The FWUPDATE utility checks the system and provides a choice (if more than one exists) of available
firmware revisions.
To download the flash components, see the HP website (
http://www.hp.com/go/hpsc
).
For more information about the One-Time Boot Menu, see the
HP UEFI System Utilities User Guide for HP
ProLiant Gen9 Servers
on the HP website (
http://www.hp.com/go/ProLiantUEFI/docs
).
FWUpdate command from within the Embedded UEFI Shell
For systems configured in either boot mode, update the firmware:
1.
Access the System ROM Flash Binary component for your server from the HP Support Center
(
http://www.hp.com/go/hpsc
). When searching for the component, always select
OS Independent
to
locate the binary file.
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
4.
Boot to Embedded Shell.
5.
To obtain the assigned file system volume for the USB key, enter
Map –r
. For more information about
accessing a file system from the shell, see the
HP UEFI Shell User Guide for HP ProLiant Gen9 Servers
on the HP website (
http://www.hp.com/go/ProLiantUEFI/docs
).
Summary of Contents for ProLiant ML350 Gen9
Page 21: ...Component identification 21 SFF drives o Tower orientation o Rack orientation LFF drives ...
Page 40: ...Operations 40 o LFF model Use a flathead screwdriver to remove the blank from the box ...
Page 122: ...Cabling 122 LFF media cage data cabling Optical device cabling SFF configuration ...
Page 126: ...Cabling 126 HP Smart Storage Battery cabling Power supply backplane cabling GPU power cabling ...
Page 128: ...Cabling 128 Embedded SATA cabling LFF configuration SFF configuration ...
Page 131: ...Cabling 131 o SFF configuration o LFF configuration ...
Page 162: ...Support and other resources 162 ...
Page 163: ...Support and other resources 163 ...