System LEDs and Switches
Table E-12: BBWCE LEDs
continued
Server Status
LED Color
LED Status
Battery Module Status
Server is on and is in the
first 30 seconds after
power-up
Amber or
green
On
Temporary lock-out state, data
was lost due to cable being
detached
Server is off and is in data
retention mode
Amber Blinking
every
15 seconds
User data held in write cache is
being backed up
CAUTION:
After the server is powered down, wait 15 seconds and then check the
illumination pattern of the LEDs before unplugging the cable from the battery module.
•
If the amber LED blinks after 15 seconds, do not remove the cable from the
battery module. This module is backing up data, and data will be lost if the cable
is detached.
•
If neither LED blinks after 15 seconds, it is safe to remove the cable from the
battery module.
When the server is on, review the POST message before plugging or unplugging the
cable from the battery module.
E-14
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Karen Hale File Name: p-appe System LEDs and Switches3.doc
Codename: Wave Part Number: 230835-003 Last Saved On: 6/26/03 9:49 AM