Memory
If a DIMM configuration error is detected, unlock the board and remove it to make
any DIMM configuration corrections. The board can then be re-inserted and the
Hot-Add procedure completed normally.
If a board insertion is aborted because of a DIMM configuration error, the Advanced
System Management Controller Driver is notified. It will log in the Integrated
Management Log (IML) and the NT Eventlog that a Board Insertion was attempted
and suffered from a DIMM configuration error.
If a DIMM configuration error is detected, the System ROM aborts the board
insertion. No negative effects exist for the system operation.
Software
The following software components of the memory system provide memory
configuration and management capabilities:
•
•
ROM-Based Setup Utility (RBSU)
Insight Manager 7
IMPORTANT:
The optional online spare memory, single-board mirrored memory, and hot
plug mirrored memory features do not require special software drivers and are operating
system independent.
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide
6-17
HP CONFIDENTIAL
Writer: Karen Hale File Name: g-ch6 Memory.doc
Codename: Wave Part Number: 230835-003 Last Saved On: 6/26/03 9:35 AM