294
User Guide Integrated Lights-Out
GET_GLOBAL_SETTINGS Runtime Errors
None
GET_GLOBAL_SETTINGS Return Messages
A possible GET_GLOBAL_SETTINGS return message is:
<GET_GLOBAL_SETTINGS>
<SESSION_TIMEOUT="120">
<ILO_FUNCT_ENABLED VALUE="Y"/>
<F8_PROMPT_ENABLED="Y"/>
<F8_LOGIN_REQUIRED="Y"/>
<REMOTE_CONSOLE_PORT_STATUS VALUE="2"/>
<REMOTE_CONSOLE_ENCRYPTION VALUE="Y"/>
<PASSTHROUGH_CONFIG VALUE=”3”/>
<HTTPS_PORT VALUE="443"/>
<HTTP_PORT VALUE="80"/>
<REMOTE_CONSOLE_PORT VALUE="23"/>
<TERMINAL_SERVICES_PORT VALUE="3389"/>
<VIRTUAL_MEDIA_PORT VALUE="17988"/>
<MIN_PASSWORD VALUE="8"/>
<REMOTE_KEYBOARD_MODEL VALUE="US"/>
<SSH_PORT value="22"/>
<SSH_STATUS value="YES"/>
<SERIAL_CLI_STATUS value="3"/>
<SERIAL_CLI_SPEED value="1"/>
</GET_GLOBAL_SETTINGS>
This reply differs from RILOE II.
MOD_GLOBAL_SETTINGS
MOD_GLOBAL_SETTINGS is used to modify global settings. For this
command to parse correctly, the command must appear within a RIB_INFO
command block, and RIB_INFO MODE must be set to write. The user must have
the configure iLO privilege to execute this command.