Remote Insight Command Language
279
•
•
•
•
•
•
•
The possible DELETE_USER errors include:
User table is full. No room for new user.
Cannot add user. The user name already exists.
User information is open for read-only access. Write access is required for
this operation.
User name cannot be blank.
User login ID cannot be blank.
Boolean value not specified.
User does not have correct privilege for action. ADMIN_PRIV required.
DELETE_USER
The DELETE_USER command is used to remove an existing local user's
account. The USER_LOGIN parameter must exist in the current user database.
For this command to parse correctly, the command must appear within a
USER_INFO command block, and USER_INFO MODE must be set to write.
The user must have the administrative privilege.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname"
PASSWORD="password">
<USER_INFO MODE="write">
<DELETE_USER USER_LOGIN="username"/>
</USER_INFO>
</LOGIN>
</RIBCL>
DELETE_USER Parameter
USER_LOGIN is the login name of the user account. This parameter is case
sensitive and must never be blank.
DELETE_USER Runtime Errors