Remote Insight Command Language
301
•
•
•
•
RIB information is open for read-only access. Write access is required for
this operation.
User does not have correct privilege for action. CONFIG_ILO_PRIV
required.
CLEAR_EVENTLOG
The CLEAR_EVENTLOG command clears the iLO Event Log. For this
command to parse correctly, the command must appear within a RIB_INFO
command block, and RIB_INFO MODE must be set to write. The user must have
the configure iLO privilege to execute this command.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<RIB_INFO MODE="write">
<CLEAR_EVENTLOG/>
</RIB_INFO>
</LOGIN>
</RIBCL>
CLEAR_EVENTLOG Parameters
None
CLEAR_EVENTLOG Runtime Errors
The possible CLEAR_EVENTLOG error messages are:
RIB information is open for read-only access. Write access is required for
this operation.
User does not have correct privilege for action. CONFIG_ILO_PRIV
required.