Remote Insight Command Language
281
•
•
<MOD_USER USER_LOGIN="loginname">
User login name was not found.
User does not have correct privilege for action. ADMIN_PRIV required.
GET_USER Return Messages
A possible GET_USER return message includes:
<RESPONSE
STATUS="0x0000"
MSG="No Errors"
/>
<GET_USER
USER_NAME="Admin User"
USER_LOGIN= "username"
ADMIN_PRIV="N"
REMOTE_CONS_PRIV="Y"
RESET_SERVER_PRIV="N"
VIRTUAL_MEDIA_PRIV="N"
CONFIG_ILO_PRIV value ="No"
/>
MOD_USER
The MOD_USER command is used to modify an existing local user’s account.
The USER_LOGIN parameter must exist in the current user database. For this
command to parse correctly, the command must appear within a USER_INFO
command block, and USER_INFO MODE must be set to write. The user must
have the administrative privilege. A user without the administrative privilege can
only modify their individual account password.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<USER_INFO MODE="write">
<USER_NAME value="username"/>
<USER_LOGIN value="newloginname"/>
<PASSWORD value="password"/>
<ADMIN_PRIV value="No"/>
<REMOTE_CONS_PRIV value="Yes"/>