WEB_AGENT_IP_ADDRESS is the address for the Web-enabled agents. The
value for this element has a maximum length of 50 characters. It can be any valid
IP address. If an empty string is entered, the current value is deleted.
SNMP_ADDRESS_1, SNMP_ADDRESS_2, and SNMP_ADDRESS_3 are the
addresses that receive traps sent to the user. Each of these parameters can be any
valid IP address and has a maximum value of 50 characters.
OS_TRAPS determines if the user should receive SNMP traps that are generated
by the operating system. The possible values are "Yes" and "No." By default, the
value is set to "No."
RIB_TRAPS determines if the user should receive SNMP traps that are
generated by the RIB. The possible values are "Yes" and "No." By default, the
value is set to "No."
SNMP_PASSTHROUGH_STATUS determines if iLO can receive/ send SNMP
request from/ to the host OS. By default, the value is set to "Yes."
CIM_SECURITY_MASK accepts an integer between 0 and 4. The possible
values are:
•
•
•
•
•
0—No change
1—None (No data is returned.)
2—Low (Name and status data are returned. Associations are present if
SNMP pass-through is supported. If not, the server and management
processor are separate entities in the device list.)
3—Medium (iLO and server associations are present but the summary page
contains less detail than at high security.)
4—High (Associations are present and all data is present on the summary
page.)
Each value indicates the level of data returned over the HTTP port.
MOD_SNMP_IM_SETTINGS Runtime Errors
The possible MOD_SNMP_IM_SETTINGS error messages include:
Summary of Contents for HP Integrated Lights-Out
Page 1: ...HP Integrated Lights Out User Guide July 2004 Sixth Edition Part Number 238882 006 ...
Page 20: ......
Page 134: ......
Page 142: ......
Page 192: ......
Page 222: ......
Page 232: ...232 User Guide Integrated Lights Out ...
Page 240: ......
Page 268: ......
Page 362: ......
Page 406: ......