![HP E4401B Programmer'S Manual Download Page 321](http://html.mh-extra.com/html/hp/e4401b/e4401b_programmers-manual_161548321.webp)
30
Con
ver
sion
Guide
HP 8590/HP ESA Spectr
um Analyz
ers Con
version Guide
LIMIMIRROR
<no equivalent SCPI command>
Reflects the current definition about the
amplitude axis at the largest frequency or the
largest sweep time in the definition.
There is no similar function in HP ESA
analyzers.
LIMIMODE
:CALCulate:LLINe[1]|2:TYPE UPPer|LOWer
Determines whether the limit-line entries are
treated as upper amplitude values, lower
amplitude values, upper and lower amplitude
values, or mid-amplitude and delta values.
LIMIREL
:CALCulate:LLINe:CMODe FIXed|RELative
Specifies the current limit lines as fixed or
relative.
LIMISEG
:CALCulate:LLINe[1]|2:DATA:MERGe
<x-axis>,<ampl>,<connected>
{<x-axis>,<ampl>,<connected>}
Adds new segments to the current frequency
limit line in either the upper limit line or the
lower limit line.
<x> is frequency in Hz.
<ampl> is amplitude in dB.
<connected>: 1 = connected, and 2 = not
connected.
HP 8590-Series
Analyzers
Command(s)
Corresponding SCPI Command(s)
Description/Comments
Summary of Contents for E4401B
Page 6: ...vi ...
Page 14: ...xiv Contents ...
Page 64: ...2 34 Chapter2 HP ESA Status Registers Using the Analyzer Status Registers ...
Page 65: ...3 1 3 Programming Examples ...
Page 151: ...4 1 4 Programming Command Cross References ...
Page 286: ...5 132 Chapter5 Language Reference UNIT Subsystem ...
Page 287: ...6 1 6 HP 8590 HP ESA Spectrum Analyzers Programming Conversion Guide ...
Page 292: ...1 HP 8590 HP ESA Spectrum Analyzers Conversion Guide ...
Page 368: ...7 1 7 Error Messages ...