![HP E4401B Programmer'S Manual Download Page 253](http://html.mh-extra.com/html/hp/e4401b/e4401b_programmers-manual_161548253.webp)
Chapter 5
5-99
Language Reference
SENSe Subsystem
triggering only.
Factory Preset
and *RST:
Positive
Front Panel
Access:
Sweep, Gate Setup, Edge Setup, Edge Pos Neg
Preset Time Gate
[:SENSe]:SWEep:TIME:GATE:PRESet
Presets the time-gated spectrum analysis capability.
Remarks:
This command resets gate parameters to default
values, as follows:
Gate trigger type = edge
Gate polarity = positive
Gate delay = 1
µ
s
Gate length = 1
µ
s
Gate level = high
Control Time Gate
[:SENSe]:SWEep:TIME:GATE[:STATe] OFF|ON|0|1
[:SENSe]:SWEep:TIME:GATE[::STATe]?
Turns time gating on or off.
NOTE
Time gate cannot be turned on if external trigger delay is on.
Factory Preset
and *RST:
Off
Front Panel
Access:
Sweep, Gate On Off
Time Gate Trigger Type
[:SENSe]:SWEep:TIME:GATE:TYPE LEVel|EDGE
[:SENSe]:SWEep:TIME:GATE:TYPE?
Selects between edge and level mode for time-gated spectrum analysis.
Level triggers the gate when the signal surpasses a specific level, set
to either low or high
Edge triggers the gate when the edge of a signal is encountered, set
to either a negative-going edge or a positive-going edge.
Summary of Contents for E4401B
Page 6: ...vi ...
Page 14: ...xiv Contents ...
Page 64: ...2 34 Chapter2 HP ESA Status Registers Using the Analyzer Status Registers ...
Page 65: ...3 1 3 Programming Examples ...
Page 151: ...4 1 4 Programming Command Cross References ...
Page 286: ...5 132 Chapter5 Language Reference UNIT Subsystem ...
Page 287: ...6 1 6 HP 8590 HP ESA Spectrum Analyzers Programming Conversion Guide ...
Page 292: ...1 HP 8590 HP ESA Spectrum Analyzers Conversion Guide ...
Page 368: ...7 1 7 Error Messages ...
Page 393: ...7 26 Chapter7 Error Messages 201 to 799 Device Specific Errors ...