16.3 Filling table for
residual areas
NOTE
•
Use the "Filling table for residual areas" to
calculate the required refill quantity for the
last spraying mixture container filling.
•
Subtract the residual quantity in the spraying
line from the calculated
refill quantity!
•
See also chapter "Spraying line"
•
The specified refill quantities apply for an ap
-
plication quantity of 100 l/ha.
•
For other application quantities the refill quan
-
tity may multiply.
Working width [m]
Travel distance [m]
18 m
20 m 21 m 24 m
27 m 28 m
30 m 32 m 33 m 36 m
10
2
2
2
2
3
3
3
3
3
4
20
4
4
4
5
5
6
6
6
7
7
30
5
6
6
7
8
8
9
10
10
11
40
7
8
8
10
11
11
12
13
13
14
50
9
10
11
12
14
14
15
16
17
18
60
11
12
13
14
16
17
18
19
20
22
70
13
14
15
17
19
20
21
22
23
25
80
14
16
17
19
22
22
24
26
26
29
90
16
18
19
22
24
25
27
29
30
32
100
18
20
21
24
27
28
30
32
33
36
200
36
40
42
48
54
56
60
64
66
72
300
54
60
63
72
81
84
90
96
99
108
400
72
80
84
96
108
112
120
128
132
144
500
90
100
105
120
135
140
150
160
165
180
Example:
Refill quantity
Remaining residual distance:
100 m
Application quantity:
100 l/ha
Working width:
21 m
Residual quantity in spraying line: 5.2 l
1.
Use the filling table to calculate the refill quan
-
tity. In the example the refill quantity is 21 l.
2. Subtract the residual quantity in the spraying
line from the calculated refill quantity.
Required refill quantity:
21 l - 5.2 l = 15.8 l
183
Summary of Contents for LEEB PT 330
Page 4: ......
Page 6: ......
Page 33: ...1 17 Position of safety stickers 33...
Page 34: ...34...
Page 187: ...Diagram a with example 187...
Page 201: ...201...
Page 202: ......