94
6-3 If a Circuit Breaker Trips
If a specific part of the machine does not work, check the
circuit breaker(s) for that part. If the breaker is tripped,
turn it ON.
Check the error code on the Error
Screen.
- Check the error code to find out which
breaker(s) have tripped.
Turn ON the breaker(s) which corre-
spond to the error code.
WARNING
Turn off the power switch before turning
ON the breaker. Otherwise, it can cause an
electrical shock.
Error No.
Location Code No.
Trouble
1121,1122,1123
1
Q50
Clamp, Level Plate Open/Close Motor M50 has trouble.
1131,1132
2
Q40
Clamper Rail Up/Down Motor M41 has trouble.
1411,1412
3
Q30
Nipper Motor M31 has trouble.
1123
4
Q20
Application Drum Motor M21, Clamp Motor M22 has
trouble.
0801
5
Q70
Delivery Motor M70 has trouble.
1801
9
Q80
Melt Tank Heater E80 has trouble.
No Error No.
6
Q60
Cover Feeder Blower Motor M61 has trouble.
No Error No.
7
Q12
Chip Extractor Motor M12 has trouble.
No Error No.
8
Q11
Milling Motor M11 has trouble.
No Error No.
9
Q01
Main Circuit Breaker has trouble.