31
3.Maintenance
3-7 Fuse Replacement
If the melt tank will not heat up, a fuse may
have burned out.
WARNINGS
- Disconnect the power cord from the
power supply before replacing a fuse,
otherwise electric shock could cause
severe personal injury.
- The melt tank is very hot after binding
operation. Wait until the tank has
cooled before replacing a fuse.
CAUTION
- Install the fuse the right way round,
otherwise it could be damaged.
1.
Turn off the power switch.
2.
Disconnect the power cord from the
power supply.
3.
Loosen 6 fixing screws and remove the
front cover.
NOTE
- Remove the small front cover (2 screws) and
then the 4 screws at the bottom of the front
cover. Tilt the cover so that the other 2 screws
can finally be removed.
4.
Remove the bottom cover of the glue tank
unit.
NOTE
- Remove the 2 fixing screws on the
operatrion side of the bottom cover and
loosen other 2 screws. Then remove the
bottom cover by sliding it to the operation
side.
5.
Replace the thermo-fuse for the glue
heater.
NOTES
- 7 mm spanner is needed to remove the nut.
-Attach the nut holding the terminal of fuse
with a long nose plier, to prevent from apply-
ing the excessive force to the fuse.
02BQ51A25
Innermost
Terminal
...........Washer
...........Nut
...........Plate
...........Fuse
...........Washer
...........Spring Washer
...........Nut
Screws
Power Switch
Front Cover
Bottom Cover
Innermost Terminal
Fuse
Summary of Contents for BQ-150
Page 1: ......
Page 5: ...IV 4 Troubleshooting 33 4 1 Troubleshooting 34 5 Installation 37 5 1 Installation 38 ...
Page 37: ...32 3 Maintenance PAGE INTENTIONALLY BLANK ...
Page 38: ...33 4 Trouble Shooting 4 Troubleshooting 4 1 Troubleshooting 34 ...
Page 41: ...36 4 Trouble Shooting PAGE INTENTIONALLY BLANK ...
Page 42: ...37 5 Installation 5 Installation 5 1 Installation 38 ...