Connection
20
Only available for 3-component specification
Only available for 2-point meter specification
TP H.Hi Conc. L1
The TP concentration for the L1 line has exceeded the final upper limit value.
TP Hi Load L1
The accumulated value of the TP load (TP concentration x flow meter) for the
L1 line has exceeded the specified upper limit value.
TN Hi Conc. L1
The TN concentration for the L1 line has exceeded the upper limit value.
TN H.Hi Conc. L1
The TN concentration for the L1 line has exceeded the final upper limit value.
TN Hi Load L1
The accumulated value of the TN load (TN concentration x flow meter) for the
L1 line has exceeded the specified upper limit value.
Hi Flow L1
The flow rate for the L1 line has exceeded the upper limit value.
Flow Mainte L1
The flow meter of the L1 is under maintenance.
Flow Err. L1
The flow meter of L1 has an error.
Flow Power L1
The power for the flow meter of L1 is down.
Flow No Drain L1
No drainage through L1 flow meter.
Item
Description
COD Hi Conc. L1
The COD concentration for the L1 line has exceeded the upper limit value.
COD H.Hi Conc. L1
The COD concentration for the L1 line has exceeded the final upper limit
value.
COD Hi Load L1
The COD load for the L1 line has exceeded the upper limit value.
Cell Motor
An error has occurred in the cell motor of the UV meter.
Lamp UV
An error has occurred in the light source of the UV meter.
CAN Comm. UV
An error has occurred during communication with the UV meter (when the
UV meter is embedded in the equipment).
Maintenance UV
The UV meter is under maintenance.
Cal. Err. UV
A calibration error has occurred in the UV meter.
COD Hi Conc. L2
Not used.
COD H.Hi Conc. L2
Not used.
COD Hi Load L2
Not used.
UV/COD Mainte L1
UV or COD meter is under maintenance.
UV/COD Err. L1
UC or COD meter has an error.
UV/COD Power L1
The power for the UV or COD meter is down.
Item
Description
Measure L2
The L2 line is currently being measured.
Samp. Lack L2
The sample water is not being supplied through the L2 line.
TP Hi Conc. L2
The TP concentration for the L2 line has exceeded the upper limit value.
TP H.Hi Conc. L2
The TP concentration for the L2 line has exceeded the final upper limit value.
TP Hi Load L2
The accumulated value of the TP load (TP concentration x flow meter) for the L2
line has exceeded the specified upper limit value.
TN Hi Conc. L2
The TN concentration for the L2 line has exceeded the upper limit value.
TN H.Hi Conc. L2
The TN concentration for the L2 line has exceeded the final upper limit value.
TN Hi Load L2
The accumulated value of the TN load (TN concentration x flow meter) for the L2
line has exceeded the specified upper limit value.
Hi Flow L2
The flow rate for the L2 line has exceeded the upper limit value.
Item
Description