62
Site Hardware
Connection to an Alarm Panel
Connect a combination of Fault Relay circuitry and outputs to an alarm panel, preset to
warn your organization if a failure occurs. An output can be configured to respond to a
Response Schedule.
Fault Relay Hardware
Figure 5-5
Connecting the DVR FAULT RELAY to an External Alarm Panel
Eleven-Minute Delay
If the DVR fails to function, report alarms or record video due to hardware failure, for more
than 11 minutes, the FAULT RELAY is triggered.
Immediate Trigger
A power outage triggers the relay immediately.
Alarm When Disabling Video Recording
A Rapid Eye LT DVR can be monitored for operator tampering with recording. Refer to the
Rapid Eye™ Hybrid HD and Hybrid LT Digital Video Recorders System Administrator Guide
,
in the tracing section.
SERIAL PORT 2
SERIAL PORT 1
VGA
TELCO
USB
USB
LAN
IN
OUT
NOT
USED
1
2
3
4
5
6
7
8
SPOT
MONITOR
VIDEO
INPUTS
CO M MON
SYS FA IL
SYS G O OD
F
AULT
RELAY
28V, 3A
MAX
1 G
G
G
G
2
3
4
CONTROL
OUTPUTS
SERIAL
PORT 3
SERIAL
PORT 4
1 G
G
G
G
2
3
4
5 G
G
G
G
6
7
8
ALARM
INPUTS
ON/OFF
POWER
115-230V~
50/60 Hz
5-3A
COMMON
SYS FAIL
SYS GOOD
F
AULT
RELAY
28V, 3A
MAX
INPUT to external
alarm panel
Not
used
Summary of Contents for Rapid Eye Hybrid LT
Page 2: ......
Page 3: ...Installation Guide ...
Page 8: ...8 Contents ...
Page 10: ...10 Figures ...
Page 12: ...12 Tables ...
Page 24: ...24 Introduction ...
Page 66: ...66 Site Hardware ...
Page 70: ...70 Frequently Asked Questions ...
Page 84: ...84 ...
Page 85: ......