Alarm Sensors
To connect alarm-type hardware to a Rapid Eye Hybrid LT DVR, use hookup wire in the
20-gauge range.
Tools you may need:
•
A slot screwdriver (supplied). The screws are smaller than those for a 1/8 inch
screwdriver.
•
A wire stripper.
Connecting an Alarm Sensor
1. From the alarm wire tips, strip approximately 0.6 cm (1/4 inch) of insulation.
2. Insert each alarm wire into the screw-type, terminal connector on the ALARM terminal
strip: one wire to the numbered terminal connection and the other wire to ground.
Caution
To avoid short-circuits, ensure that bare wire is not visible at the rear panel.
Inputs for Sensors
Configuration Using View Software
1. Using View, start a Maintenance session for the Rapid Eye site. Wait until the
System
Operational
message appears. Click the
Events
tab. More tabs are displayed.
2. Click the
Inputs
tab.
3. Enter the name of an input in its Input box. You have the option of identifying inputs
that are not in use, such as input 7 and input 8 (see
4. You have the option of monitoring the activation of inputs and their deactivation by
selecting
Log
and
Alarm
, as needed.
5. By default, alarm/control inputs are configured as NO (normally open). Click
NC
(normally closed) or
EOL
(end-of-line), as needed.
Summary of Contents for Rapid Eye Hybrid LT
Page 2: ......
Page 3: ...Installation Guide ...
Page 8: ...8 Contents ...
Page 10: ...10 Figures ...
Page 12: ...12 Tables ...
Page 24: ...24 Introduction ...
Page 66: ...66 Site Hardware ...
Page 70: ...70 Frequently Asked Questions ...
Page 84: ...84 ...
Page 85: ......