Rapid Eye™ Hybrid LT DVR Installation Guide
Document 800-07766V4 Rev A
33
01/2013
Unit Recovery
Unit recovery is an internal diagnostic that seldom occurs and cannot be interrupted, even
by powering down the DVR. A unit recovery can take many hours, even dozens of hours on
DVRs with a large storage capacity. If unit recovery occurs repeatedly, contact Honeywell
Technical Support (see the back cover of this manual for contact information).
Rapid Eye LT Unit Installation Environment
Installation of the equipment in a partially or completely enclosed space (such as a
multi-unit rack or lock box) should be such that the amount of air flow required for safe
operation of the equipment is not compromised.
Caution
If the unit is installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
The following guidelines must be followed when installing your Rapid Eye Hybrid LT unit:
•
There must be at least 1 inch of clear, unobstructed space around the front, rear and
sides of the unit (see
) to allow for sufficient air flow around the Rapid Eye
Hybrid LT unit during operation.
•
Intake and exhaust vents in the enclosure should align with the intake and exhaust
vents on the Rapid Eye Hybrid LT unit to maintain proper air flow (see
•
During operation, the maximum ambient temperature measured directly at the air
intake vent of the Rapid Eye Hybrid LT unit must never exceed the maximum
operating temperature of 104°F (40°C).
Summary of Contents for Rapid Eye Hybrid LT
Page 2: ......
Page 3: ...Installation Guide ...
Page 8: ...8 Contents ...
Page 10: ...10 Figures ...
Page 12: ...12 Tables ...
Page 24: ...24 Introduction ...
Page 66: ...66 Site Hardware ...
Page 70: ...70 Frequently Asked Questions ...
Page 84: ...84 ...
Page 85: ......