| 57
Document 800-26311_ A - April 2020
Figure 2-31 Configuring Output Groups
2. Click to
add a new group.
3. Configure the following for each output group:
4. Click toggle(s) to select outputs. Click the
Choose Outputs
toggle to select all
outputs.
5. Click
Save
.
Configuring Card Formats
A card format tells the panel how the card number will be read. The panel supplies the
format to the card readers. Then, the card readers can correctly read the card.
Setting
Description
Name
Enter a unique name for the group
Pulse Time
Configure how long a device assumes abnormal status, such
as a horn sounding or a released door strike. In
hours:minutes:seconds. Maximum time is 1:45:59.
Latch
Toggles the state of the outputs between energized and
de-energized status upon every activation (code use, interlock,
or manual pulse).
Energized
Specifies the period during which the group of output relays
are automatically energized. Select a schedule (that you
Entering a Panel Name on page 28
) from the
drop-down list.
Disable Interlocks
Specifies the period during which the interlocks that control
the group’s outputs will be disabled. Select a schedule (that
Entering a Panel Name on page 28
) from the
drop-down list.