| 95
Document 800-26311_ A - February 2020
Synchronizing a New Panel with Information on an Existing
Panel
No special operation is required. For any new secondary panel added in a loop,
Primary Panel will push card and common configuration to the new panel so basic
databases will already be synced up once panel is detected/added.
Note
The secondary panel will reboot after the panel is synchronized.
Primary panel to the Secondary panel synchronization occurs at the time the
Secondary panels are “Registered” with the Primary and will include the
common data.
Replace a Primary Panel in an Existing Loop (Web Mode)
Overview
Details the steps to replace a MPA1 "Primary" panel with existing "Secondary" panels which
is connected to the Ethernet Virtual Loop (EVL). The System Wide Restore in the Primary is
required with an existing backup.
Primary Panel Replacement and System Wide Restore
IMPORTANT:
Ensure a "System Wide Backup" is performed prior to replacing the Primary
Panel.
Step # 1.
Power up the "New" Primary panel and log into the Web Interface.
Step # 2.
Hard Default the "Secondary" panels as they are bound to the original Gateway
panel.
Step # 3.
Navigate to the "Advanced" Tab of the primary panel:
•
EVL Installations:
Requires Manual Registration of the Secondary Panels.
• Navigate to the EVL Discovery and "Register" the Secondary Panels.
IMPORTANT:
In order to proceed to Step #4 please wait for all panels to be synchronized.
Refer to the "Synchronization Detail Chart"
Step # 4.
Select the "Restore Entire Loop" option from the "System Wide Backup" once all
of the Secondary panels are registered with the Primary.
•
Refer to the "Restore Entire Loop Detail Chart"
Summary of Contents for MPA1
Page 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Page 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...