www.honeywell.com/security
50 |
MPA1 User Guide
Configuring Door Outputs
The Outputs tab allows you to configure the following settings:
1. Discrete or Group selection
2. Output Name and Pulse Duration
3. Latch and Interlocks
4. Special output modes controlled by cards
5. Lock operation definition
6. Scheduling
Two outputs are associated with the door on a MPA1 panel
1.
Lock
- Controls the lock in an electronic state to open or close the door (Default SWITCHED GND)
2.
Reader LED
-Controls the LED of the Reader(s) in Green state (via OSDP command)
The Outputs tab allows you to configure the following settings for the door
1. Select Discrete Output or Output Group and number
2. Define Output Name
3. Specify Pulse duration
4. Disable or Enable Latched output after valid card (instead of pulse)
5. Disable or Enable Interlocks.
6. Disable or Enable Card activity outputs mode such as Time Zone Card Toggle and
First Card Rule
7. Specify Lock Operation as Fail Safe or Fail Secure
8. Specify Schedules for Energized output and for Disable Interlocks
Click Outputs in the
Doors
configuration window to open the outputs configuration pane
Figure 2-27 Door Output Configuration Interface.
Summary of Contents for MPA1
Page 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Page 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...