| 71
Document 800-26311_ A - April 2020
Note
A PIN is optional; however, if the door reader is configured to require PIN
Configuring Door Reader Settings on page 43
), then you
must create a PIN for the card holder here. The PIN has a maximum of six
digits.
Note
If you are adding multiple cards, then you cannot enter a PIN/Password.
4. Turn
Trace
on or off.
Trace provides a record of the person’s path through the facility by sending an alarm
message to the
Alarm & Events screen
whenever a card with trace enabled is
presented at a reader.
5. Select a type of
Usage
.
a. If you select
Temporary
, then you must select from the calendar an end date for
the temporary card.
b. If you select
Limited
, then you must enter the maximum number of accesses
granted to the temporary card, between 1 to 255.
6. Select an
Card Type
: Employee, Supervisor, or VIP.
Note
Once a VIP card is added to the database, it can gain access to any door
regardless of the access level. VIP card can also bypass Duress,
Anti-Passback, Disabled Reader Mode, Duress, Limited Use, Lockdown
Reader Mode, Site Code, and Temporary Use.
7. Click
Save
.
Modifying Cards