MPA1 User Guide
Table 7-4
Overriding requirements
Yes/No
Grade 1 OP/M
The electronic access control system shall not prohibit the free exit granted by
other emergency systems (e.g. fire, environmental)
Yes
M
Table 7-5
System self-protection requirements
Yes/No
Grade 1 OP/M
Memory stored information (settings) shall be kept for the indicated minimum
period of time in case of total power loss (except for loss of data retention
battery)
Yes
M
Following a total loss of power automatic restart of the access control system is
required upon primary power source restoral
Yes
M
If full functionality of the access control unit cannot be restored (data
corrupted or lost) following the automatic restart a trouble condition shall be
annunciated
Yes
M
Means of access to the internal elements of components of an access control
system shall require the use of a tool
Yes
M
The enclosures of the EACS components accessible from outside the controlled
area shall meet the required IP and IK ratings
Yes
M
There shall be separate access levels that categorize the ability of the operators
to perform different functions in the system. Minimum number of logical
access levels is:
Yes
M
The minimum number of required characters for logical access by memorized
information only shall be as indicated (N=numeric/A=alphanumeric)
Yes
M
Either failure or restoration of the communication channel shall not result in
the release of an access point
Yes
M
Failure of communication with monitoring console shall not interrupt the
access decision process
Yes
M
Processing rules stored in an access point reader shall not be visible to system
users
yes
M
Light or sound keystroke keypad activation indicators shall not be a direct
representation of actual codes, but shall be identical in pitch and duration
Yes
M
Data entry system validation. System shall provide annunciation when invalid
data has been entered during configuration mode at the monitoring console
Yes
M
Access to the configuration mode shall time out after a pre-set period of
inactivity
Yes
M
Table 7-6
Power supply requirements
Yes/No
Grade 1 OP/M
Following an extended primary power source failure (system shutdown
occurred) and restoration of power, rechargeable batteries shall be recharged
to 80 % of rated capacity within 24 hours and 100 % of rated capacity within
72 hours
N/A
M
Summary of Contents for MPA1
Page 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Page 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...