1. Navigate to the
Outputs
tab: Click
Panel Configuration
>
Outputs
>
Individual
.
Figure 2-30 Configuring Individual Outputs
2. Click to select an individual output from the list.
3. Configure the following for each output:
Setting
Description
Name
Enter a unique name for the output
Pulse Time
Configure how long a device assumes abnormal status, such
as a horn sounding or a released door strike. In hours, minutes,
and seconds. Maximum time is 1:45:59.
Latch
Toggles the state of the outputs between energized and
de-energized status upon every activation (code use, interlock,
or manual pulse).
Interlocks
Disable/enable interlocks. See
Configuring Interlocks on page
for more about Interlocks.
Lock Operation
Specifies the output to function in Fail Secure, or Fail Safe
mode in (default) Fail Secure mode output in normal state is
not active. A lock that needs to be powered to unlock a door will
use the Fail Secure mode. If the MPA1 is not powered the
output and lock remains in it normal state. In Fail Safe mode
the output in the normal state is activated. A lock that needs to
be Powered to lock the door (e.g a magnetic lock) will use the
Fail safe mode, If the MPA 1 is not powered the output and lock
remains in its abnormal state and releases the lock.
Note
The MPA1 does not have the jumpers to provide Fail
Safe operation of the lock
Summary of Contents for MPA1
Page 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Page 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Page 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...