IGSMV
/
IGSMVCN Installation and Setup Guide
1-4
The control treats the module as 4204 Relay Module(s), so program the control
accordingly, including setting the module’s proper 4204 device address
4204 mode provides up to four zone inputs, plus two optional trigger zones, depending on
options programmed
Two-4204 mode provides up to eight zone inputs, depending on options programmed
Each 4204 zone can be programmed for delayed reporting and restoral reporting
Reports are sent in ADEMCO High-Speed format
UL
4204 Mode and Two-4204 Mode has not been evaluated by UL.
Module Supervision Features
The IGSMV provides the following types of supervision and module fault detection:
Network communication failure: In the event the AlarmNet network does not hear a
supervisory message from the module within a specified time, AlarmNet notifies the
central station of a communication failure.
Communication path failure: In the event the module detects a communication path
failure, the control panel can be notified of a trouble condition with the module after a
specified time has elapsed (“GSM Flt Time” option, 00-99 minutes).
Fault output: Terminal 11 can serve as a fail-safe trigger for module fault conditions.
If used, the fault relay will trip when the following conditions occur: tamper*, power loss*,
low battery*, battery charger fault*, loss of network connectivity*, the device is not
registered and the device is remotely disabled by AlarmNet.
*
Alarm reporting for the noted condition must be enabled for it to trigger the fault relay.
Primary power loss and low battery conditions (“Pwr Loss Rpt,” “Low Bat Rpt” options).
Cover tamper condition (“Tamper Rpt” option).
Antenna
The IGSMV comes equipped with an internal antenna. This feature provides additional
security to the installation by making the device tamper resistant.
UL/ULC
External antenna has not been evaluated by UL.
AMPS antennas, such as the 7825-OC antenna, cannot be used with this product.
Specifications
Mechanical
Dimensions: 8.4" x 8.0" x 1.5"
Weight: 2.4 lbs., with battery
Electrical
Input Power: 16.5VAC, 40VA transformer, Honeywell model No. 1361 (included)
Current Drain: 65mA average standby, 500mA peak transmit
Or
Input Power for ULC Installations: 12VDC from the control panel
Current Drain: 80mA average standby, 650mA peak transmit
Summary of Contents for AlarmNet IGSMV
Page 2: ......
Page 20: ...IGSMV IGSMVCN Installation and Setup Guide 2 10 ...
Page 46: ...IGSMV IGSMVCN Installation and Setup Guide 4 4 ...
Page 54: ...IGSMV IGSMVCN Installation and Setup Guide A 2 ...
Page 56: ...IGSMV IGSMVCN Installation and Setup Guide B 2 ...
Page 58: ...IGSMV IGSMVCN Installation and Setup Guide C 2 ...
Page 60: ...IGSMV IGSMVCN Installation and Setup Guide D 2 ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...