IGSMV
/
IGSMVCN Installation and Setup Guide
3-18
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY
OPTIONS
DESCRIPTION
37
Invert Zn2 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the
zone 2 trigger; otherwise uses normal input
signal.
38
Restore Zn2 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 2.
UL/ULC:
Must be set to “Y.”
39
Delay Zn2 (secs)
(00)_
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 2.
UL/ULC:
Must be set to “00.”
40
Rpt Zn2 ONLY if
Armed (N)_
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 2.
If Lynx Panic is enabled, then skip to Prompt 45: "Rpt Zn3 ONLY if Armed."
41
Zn3 Trigger Type
(V+)_
(V+)
(V–)
(EOLR)
Selects the triggering method for this zone
input.
Press the [space] key to scroll through
choices.
UL:
V+ must be set as inverted and V– as
non-inverted.
42
Invert Zn3 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the
zone 3 trigger; otherwise uses normal input
signal.
43
Restore Zn3 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 3.
UL/ULC:
Must be set to “Y.”
44
Delay Zn3 (secs)
(00)
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 3.
UL/ULC:
Must be set to “00.”
45
Rpt Zn3 ONLY if
Armed (N)_
[Y], [N]
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode:
If any zone is programmed to
"Report Only if Armed," skip to Prompt 56:
"Enable Zn6."
46
Zn4 Trigger Type
(V+)_
(V+)
(V–)
(EOLR)
Selects the triggering method for this zone
input.
Press the [space] key to scroll through
choices.
UL:
V+ must be set as inverted and V– as
non-inverted.
47
Invert Zn4 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the
zone 4 trigger; otherwise uses normal input
signal.
48
Restore Zn4 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 4.
UL/ULC:
Must be set to “Y.”
49
Delay Zn4 (secs)
(00)
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 4.
UL/ULC:
Must be set to “00.”
Summary of Contents for AlarmNet IGSMV
Page 2: ......
Page 20: ...IGSMV IGSMVCN Installation and Setup Guide 2 10 ...
Page 46: ...IGSMV IGSMVCN Installation and Setup Guide 4 4 ...
Page 54: ...IGSMV IGSMVCN Installation and Setup Guide A 2 ...
Page 56: ...IGSMV IGSMVCN Installation and Setup Guide B 2 ...
Page 58: ...IGSMV IGSMVCN Installation and Setup Guide C 2 ...
Page 60: ...IGSMV IGSMVCN Installation and Setup Guide D 2 ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...