IGSMV
/
IGSMVCN Installation and Setup Guide
3-10
Alternative Modes (Zone Trigger, 4204 and Two-4204)
UL
/
ULC
The LYNX controls have not been evaluated with this communication module.
Zone Trigger Mode
There are six input zones available on the IGSMV. Each zone is selectable for +V, -V, or
EOLR trigger. The first zone input can detect both pulsed and steady signals if connected to
a bell output. Additionally, the first zone input can be programmed to detect a single pulse
(characteristic of a Panic indication on the Lynx, LynxR or LynxR-EN control panel by
enabling the Lynx Panic option). If the programming option “Lynx Panic” is enabled, the
IGSMV reports an alarm on zone 3. No restores are reported for this zone. If this option is
selected, the second physical zone input is ignored.
When using Zone Trigger mode, messages are sent in ADEMCO High-Speed format.
Zones 3, 4, 5, 6 and 7 are voltage trigger inputs located on TB1 pins 6-10. If the Lynx Panic
feature is being used, do not connect zone 3 (the second physical zone input).
Refer to Table 3-4 for Zone Trigger Mode programming and follow the prompts that pertain
to Zone Trigger Mode.
A check mark (
) indicates whether the prompt applies to that mode.
4204 Emulation Mode
In 4204 Emulation Mode, the IGSMV communicates with a compatible Honeywell VISTA
series or First Alert control panel as though it were a 4204 Relay Module. If two 4204s are
enabled in the module, it acts as two 4204s at consecutive device addresses. The control
panel must be configured to recognize one or two 4204 relay modules accordingly. On
VISTA-32FB (or higher) control panels and First Alert equivalents, addresses 6 and 13
should not be used when the secondary 4204 is enabled. Messages are sent in ADEMCO
High-Speed format.
NOTE:
See your control panel Installation and Setup Guide for the number of 4204 modules
supported.
4204 Emulation Mode Options
For control panels that do not support LRR-ECP communication, the 4204 Emulation modes
provide a means of sending up to eight unique reports based on defined system conditions. In
4204 mode, the IGSMV functions as a logical 4204 Relay Module, where each relay number,
referred to in the module as zone number, can be programmed to send a report based on the
output function programmed in the control panel for that relay. Each relay-zone can also be
programmed to send a restore message of the reported condition, can be set to delay
transmission of messages, and can be programmed to send reports only when a conditional
zone is triggered (armed), (see
Important Information Regarding
Zone Input Options
later in
this section).
In single 4204 mode, the IGSMV supports up to four relay-zones. In Two-4204 mode, the
IGSMV functions as two 4204 modules, supporting up to eight relay-zones.
UL
4204 Mode and Two-4204 Mode has not been evaluated.
4204 Relay Outputs map to IGSMV zones as follows:
First 4204 Zones
(device address entered in Prompt 14)
:
Second 4204 Zones
(device address entered in Prompt 14, plus 1)
:
Relay 1 = Zone 1
Relay 2 = Zone 2
Relay 3 = Zone 3
Relay 4 = Zone 4 or conditional zone trigger if
“report only if armed” is selected in any zone 1-3
when using single 4204 mode.
Relay 1 = Zone 5
Relay 2 = Zone 6
Relay 3 = Zone 7
Relay 4 = Zone 8 or conditional zone trigger if
“report only if armed” is selected in any zone 1-7
when using Two-4204 mode.
Summary of Contents for AlarmNet IGSMV
Page 2: ......
Page 20: ...IGSMV IGSMVCN Installation and Setup Guide 2 10 ...
Page 46: ...IGSMV IGSMVCN Installation and Setup Guide 4 4 ...
Page 54: ...IGSMV IGSMVCN Installation and Setup Guide A 2 ...
Page 56: ...IGSMV IGSMVCN Installation and Setup Guide B 2 ...
Page 58: ...IGSMV IGSMVCN Installation and Setup Guide C 2 ...
Page 60: ...IGSMV IGSMVCN Installation and Setup Guide D 2 ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...