Section 3: Programming the IGSMV
3-17
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY
OPTIONS
DESCRIPTION
31
Telco Zone
(0)_
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
See Important Information Regarding Zone
Input Options on previous page.
Enter the zone number to be used for Telco
line fault reports. This zone assignment must
be unique from the open/close zone selected in
Prompt 32.
Zone Trigger Mode:
If any zone is
programmed for "report only if armed,"
zone 7 cannot be used. If Lynx Panic is
enabled, zone 3 cannot be used.
4204 Mode:
If any zone is programmed for
"report only if armed," zone 4 cannot be
used.
2-4204 Mode:
If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used.
NOTE:
Connect the Telco line fault output (or
relay output programmed for "Telco line
fault") to the Telco zone.
32
Open/Close Zone
(0)_
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
Enter the zone number to be used for
open/close (arm/disarm) reports.
This zone assignment must be unique from
the Telco zone selected in Prompt 31.
Zone Trigger Mode:
If any zone is
programmed for "report only if armed,"
zone 7 cannot be used as an open/close
zone. If Lynx Panic is enabled, zone 3
cannot be used.
4204 Mode:
If any zone is programmed for
"report only if armed," zone 4 cannot be
used as an open/close zone.
2-4204 Mode:
If any zone is programmed for
"report only if armed," or if tamper is
enabled, zone 8 cannot be used as an
open/close zone.
NOTE:
Connect an open/close (arm/disarm)
trigger (or relay output) from the control
panel to the open/close zone.
33
Zn1 Trigger Type
(V+)_
(V+)
(V–)
(EOLR)
Selects the triggering method for this zone
input.
Press the [space] key to scroll through
choices.
UL:
V+ must be set as inverted and V– as
non-inverted.
34
Restore Zn1 Y/N
(Y)_
[Y], [N]
Enables restore reporting for zone 1.
UL/ULC:
Must be set to “Y.”
35
Delay Zn1 (secs)
(00)_
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 1.
UL/ULC:
Must be set to “00.”
36
Rpt Zn1 ONLY if
Armed (N)_
[Y], [N]
Report alarms on zone 1 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; or zone 8 in 2-4204
mode) is triggered (armed).
If [N], always reports alarms on zone 1.
Summary of Contents for AlarmNet IGSMV
Page 2: ......
Page 20: ...IGSMV IGSMVCN Installation and Setup Guide 2 10 ...
Page 46: ...IGSMV IGSMVCN Installation and Setup Guide 4 4 ...
Page 54: ...IGSMV IGSMVCN Installation and Setup Guide A 2 ...
Page 56: ...IGSMV IGSMVCN Installation and Setup Guide B 2 ...
Page 58: ...IGSMV IGSMVCN Installation and Setup Guide C 2 ...
Page 60: ...IGSMV IGSMVCN Installation and Setup Guide D 2 ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...