133
Section 5 - Scheduled Maintenance
6. Shutdown the water blasting system and
return the truck to the service position.
7. Install spray bar
8. At this point you’re ready to continue with
complete startup procedure. (Refer to the
System Startup Procedure in Section 3)
NOTICE:
IF YOU ARE INTENDING TO REUSE THE RECOVERED
ANTIFREEZE, MAKE SURE TO TEST IT AND MAKE SURE THE
ANTIFREEZE MIXTURE HAS NOT BECOME DILUTED TO THE
POINT WHERE IT WILL NOT PROTECT THE WATER SYSTEM
AT THE EXPECTED TEMPERATURES.
REMEMBER THAT THE ANTIFREEZE WILL BE SLIGHTLY
DILUTED EACH TIME THE SYSTEM IS WINTERIZED, WHICH
WILL CAUSE THE FREEZE PROTECTION TEMPERATURE TO
RISE. THE AMOUNT OF DILUTION WILL VARY, DEPENDING
ON THE VOLUME OF FRESHWATER IN THE SYSTEM AT THE
TIME OF WINTERIZATION.
CAUTION
TO AV O I D S E R I O U S D A M A G E TO WAT E R B L A S T I N G
HYDRAULIC COMPONENTS WHEN OPERATING IN FREEZING
TEMPERATURES OR TEMPERATURES BELOW 60 DEGREES
FAHRENHEIT (16
0
CELSIUS), IT IS NECESSARY TO OPERATE
THE HYDRAULIC SYSTEM AND OTHER WATER BLASTING
C O M P O N E N T S I N C L U D I N G T H E B L O W E R A N D H I G H
PRESSURE PUMP, WITH THE ENGINE AT IDLE, UNTIL THE
HYDRAULIC FLUID REACHES A TEMPERATURE OF 60
DEGREES FAHRENHEIT (16 DEGREES CELSIUS) OR ABOVE.
Summary of Contents for SK5500
Page 2: ......
Page 80: ...80 NOTES...
Page 135: ...135 Section 5 Scheduled Maintenance Hog Technologies...
Page 141: ...141 Appendix 2 Tools Spare Parts...
Page 142: ...142 Appendix 2 Tools Spare Parts...
Page 143: ...143 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM...
Page 152: ...152 NOTES...
Page 159: ......
Page 160: ......