93
Section 4 - General Maintenance
9. Install the nozzles into the spray bar being
careful not to get any anti-sieze on the seat
area of the nozzle or the spray bar.
10.
Tighten each nozzle finger tight, then torque
to 10 ft lbs.
11. Reactivate the truck and water blasting sys-
tem by following the steps in the Start Up
Procedure.
12. Set the Head Rotation speed dial to 0, then
follow the procedure to activate the ultra-high
pressure water system.
13. Make sure all personnel are well clear of the
blasting head, then press the DUMP VALVE
switch to activate the high pressure system
and set the operating pressure to a safe level.
Staying well clear of the water jets, no closer
than 18”, visually inspect the spray pattern of
each nozzle.
14.
Confirm at least a 1 inch, needle tight, water
jet is coming from each nozzle.
15. Deactivate the water blasting system and
place the truck in the service position.
16. Install the spray bar protective cover and
gasket.