background image

 

 

New All-Purpose Door Guard 

 

NUDV - 00 
NUDV - 01 
NUDV - 02 

NC - mod4 

NM - mod4 

NKLA 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

Installation and Operating Instructions 

 

Summary of Contents for NC - mod4

Page 1: ...New All Purpose Door Guard NUDV 00 NUDV 01 NUDV 02 NC mod4 NM mod4 NKLA Installation and Operating Instructions ...

Page 2: ......

Page 3: ...ed by NC mod4 and NM mod4 modules up to 64 buttons using the basic mechanical MK1 MK4 units The whole assembly can be completed with cover frame or rain protective canopy both under plaster and on plaster The guard is supplied from branch exchange line his features remind a loud telephone The basic features include the possibility to open up to two doors by means of connected electrical locks the ...

Page 4: ... OVERVIEW 14 2 2 VISITOR AT DOOR 14 2 2 1 Guard without Keyboard 14 2 2 2 Guard with Keyboard 15 2 3 PERSON INSIDE OBJECT 16 2 3 1 Outgoing Call 16 2 3 2 Incoming Call 16 3 PROGRAMMING OF PARAMETERS 17 3 1 PROGRAMMING THROUGH PHONE 17 3 1 1 Entry to Programming 17 3 1 2 Programming of parameters 17 3 2 PROGRAMMING FROM PC PROGRAM NSET 18 4 DESCRIPTION OF PARAMETERS 19 4 1 DIRECT DIALING MEMORIES 1...

Page 5: ... 5 TECHNICAL PARAMETERS 31 5 1 ELECTRICAL PARAMETERS 31 5 2 MECHANICAL DIMENSIONS 31 6 TABLE FOR EASY PROGRAMMING 32 7 DECT DISTYBOX 35 7 1 DISTYBOX DESCRIPTION 35 7 2 DISTYBOX SIGNALING 35 7 3 DISTYBOX PROGRAMMING 36 7 4 LOG ON TO BASE STATION 36 ...

Page 6: ...from telephone Ø Six code locks password from buttons at the door Ø Possibility to connect a numerical keyboard this way that the guard can include 0 18 standard buttons Ø Keyboard mode could be either direct dialing or dialing from memory Ø Optional number of rings before taking an incoming call Ø Optional time among button pressing by code entry Ø Optional time of hanging up when the choice is r...

Page 7: ... numerical keyboard and camera module The complete assembly consists similarly to UDV system of max 4 modules in column and max 3 columns side by side NUDV2 NUDV1 NUDV0 NC M mod4 Camera IP Fixing KPD2 rain Canopy2 Flanging frame2 frame 2 protective cover flush mounted flush mounted on plaster By flush mounted assembly the MK 1 to MK 4 boxes are used as well as with UDV system MK 2 Analog camera NK...

Page 8: ...3 Module Features 1 3 1 NUDV Basic Module The NUDV basic module is supplied in three variants with two NUDV2 buttons one NUDV1 button and without buttons type NUDV0 V1 x Fig 1 Rear view of basic module Fig 2 Rear view of setting parts in version V6 x ...

Page 9: ...ends on number of modules since it simultaneously serves feeding of lighting through visiting cards at max number of connected modules the demand will not exceed 300mA This source can be also used for feeding of lock s and then it is necessary to consider the electrical lock demand In practice the alternating feeder 12V 1A mostly meets these demands The connection of switch contact terminals is sh...

Page 10: ...g next is necessity gain of trimmer MIC make smaller Procedure of setting trimmer SPK setting to maximum turn to the right trimmer MIC on minimum and at conversation connection subscriber speaking in building permanent talk trimmer MIC turning to the right until sound from speaker begins interrupt next gain teeny reducing moving round a slight amount left It shall everything be all right For newer...

Page 11: ...or connection of other four buttons and current supply of lighting are further placed on module on following NM mod4 The NM mod4 module is always connected to previous in row starting with basic module NC mod4 The connection is not prepared and should be done by conductors see on figure 4 The flat cable connection is facilitated by connector locks preventing from rotation but to keep the connectio...

Page 12: ...tly specified parameter 48 The choice is entered by gradual pressing of buttons with digits Firstly the key symbol must be pressed to enter a password When pressing X the guard will hang up Rem From version of firmware 7 8 makes it possible dial DTMF dialing during talk from keyboard 1 3 4 Other modules Other modules extending the guard assembly are actually offered on www alphatech cz and can be ...

Page 13: ...h external installation at swift temperature changes and higher air humidity by switched heating no water condensation occurs on basic guard board which assures its reliable function 1 5 Change of nameplates The first step is dismantling of a fixing frame from module where we want to change a nameplate It can be executed by unscrewing of two screws under plastic covers on fixing frame When removin...

Page 14: ...ll end 1275 glows Entry to programming from phone 850 glows Programming from phone mod 850 glows Parameter confirmation glows Entry to programming from PC 850 glows Programming from PC blinks Connection to line Reset 1275 850 1275 blinks Error anything if unsuitable 425 Empty memory no progr numb 850 1275 1700 2 2 Visitor at Door The all purpose guard function is influenced partly by used guard as...

Page 15: ...combination that meet the preprogrammed code parameters 32 34 and the time among presses is not bigger than the set point parameter 53 then the guard will lift up and close the corresponding switch if set in m 1 or m 5 modes to the period given by parameter 36 event 38 Then it will hang up 2 2 2 Guard with Keyboard The guard with keyboard can also include besides the keyboard up to 18 buttons of d...

Page 16: ...or The code choice can close the switch parameter 35 if set to m 1 or m 5 modes change over the Day Night modes parameters 45 46 and hang up parameter 43 The guard in 10 seconds before call end parameter 52 will send a notice about call end and the call may be extended by sign selection parameter 42 The telephone hanging up will end the call the exchange is sending a busy tone on guard s line and ...

Page 17: ... by programming tone and the guard will come back to this state always after time expiration 5 seconds even you started to program anything When programming two types of parameters will occur Partly they are parameters with fixed length the majority of them they are then the programming is affirmed and the parameter is always recorded immediately after mandatory length fulfillment by acknowledge t...

Page 18: ...ct the NUDV to the line Line the guard with PC by KAB cable if PC serial port absent the USB COM reduction is to be used The guard will answer and LED light on the front panel will light Run the Nset program the guard will report the his conversion to PC programming mode viz chapter 2 1 page 14 After Nset program being run the guard is in this mode this status is indicated by LED light on front pa...

Page 19: ...4 nn telephone number up to 16 digits we want to store To store other choice flags the assignment given in table is used The numbers stored in parameter 2 are the number of the second group or numbers of Night mode Neither basic setting do not change or delete the stored numbers Note The switchover to Day Night mode remains set in guard even after line disconnection List of related parameters 41 4...

Page 20: ...ch closing from buttons or keyboard 2 to 6 digits Total 6 passwords they are controlled by Day Night the combination is entered either by guard buttons first 10 buttons or from attached keyboard after pressing of key symbol The switch closing influences the set switch mode and Day Night switchover By setting of choice mode of 2 number groups the guard is permanently in DAY mode By password choice ...

Page 21: ...lowed or p 0 prohibited to control the switch during incoming call To prohibit the control during incoming call is important e g when using switch 2 in mode 1 for control of garage gate opening when the electronics opens the gate and the gate is closed by car passage Then the control from phone could undesirably cause the permanent gate opening not closed no car passage List of related parameters ...

Page 22: ... aa bb List of related parameters 35 8 84 Parameter Value Meaning Basic 44 xxxx service password 0000 xxxx service password for entry to programming List of related parameters 8 84 Parameter Value Meaning Basic 45 dd command for DAY switching 11 46 nn command for NIGHT switching 10 dd command for DAY mode switching 2 digits nn command for NIGHT mode switching 2 digits Note The switchover to Day Ni...

Page 23: ...son is stored memory number corresponds to button number with respect to Day Night switchover ATTENTION This parameter setting will sharply influence keyboard function List of related parameters 1 2 47 48 53 8 84 This parameter is avalaible only in version firmware 7 8 Parameter Value Meaning Basic 40 d dialing DTMF from keyboard during talk 0 d d 0 dialing DTMF from keyboard during talk is disabl...

Page 24: ...y this w time keyboard switch closing if time between two next presses is bigger than w time the code is not evaluated correctly dialing dialing the same as of phone if time after the last pressed button is bigger than w time then the dialing starts If the number is incomplete it is necessary to hang up X button and the dialing will be repeated dialing from memory if time following the first press...

Page 25: ...of 2 groups is set List of related parameters 47 8 85 Parameter Value Meaning Basic 57 t DTMF tone duration tone choice 5 100ms 58 m gap duration among DTMF tones 5 100ms 59 f Flash duration 1 100ms 50 p pause duration interdigit gap 8 800ms t DTMF tone duration is determined per formula entered number 5 x 10 tone duration ms range 1 0 i e 60 150ms m gap duration among DTMF tones is determined per...

Page 26: ...ly for parameters 3x only 3 84 basic setting only for parameters 4x only 4 85 basic setting only for parameters 5x only 5 The parameters 81 and 82 will execute deleting of all numbers stored in memories for buttons The parameters 83 85 will execute a selective basic setting only for parameters starting with 3 5 ATTENTION the deleting is non reversible It is then necessary to program it again 4 6 P...

Page 27: ...itted with 2 buttons Atention This parameter does not basically affect the correct function of guard Parametr Value Description Basic 6 z Switching off acoustic signalization 3 In default is status of Door phone signalling acoustically It can cause a problem of incorrect detection of tones by PBX By parametr z you can switch off this acoustic signalization The values are z 0 all signalling is swit...

Page 28: ...5 37 r p r switch control by incoming call 11 21 38 xx xx period sec between switches 1 and 2 closing 10 41 v choice type v tone pulse 0 42 z sign for call extension 43 g bb command for guard hanging up from phone 155 266 44 xxxx service password 0000 45 dd command for DAY switching 11 46 nn command for NIGHT switching 10 47 e mode of guard choice 1 48 c keyboard connection 0 49 o keyboard mode 0 ...

Page 29: ...s 59 f Flash duration 1 100ms 50 p pause duration interdigit gap 8 800ms 8 basic setting executes 81 deletes all numbers in group 1 Day mode 82 deletes all numbers in group 2 Night mode 83 basic setting only for parameters 3x only 3 84 basic setting only for parameters 4x only 4 85 basic setting only for parameters 5x only 5 9 E N D ...

Page 30: ...uring oper 10 sec choice DTMF sign of call extension hanging up from phone 1 2 55 66 service password 0000 switching to day mode 11 switching to night mode 10 guard choice mode Day Night keyboard connection no keyboard mode dialing number of rings of incoming call 2 max call time 2 min time among button presses 2 sec time of hanging up when dialing repeated 2 sec time before dialing 1 sec number o...

Page 31: ...evel 4 a 6 dB 20 60 mA Tone choice sensitivity 40 dB 20 60 mA Sensitivity of tone detector 30 dB 20 60 mA Power supply of lighting through switches and heating 12Vss 2V 10 12Vst 2V Max consumption of lighting through and heating 300mA 12Vss Max voltage of switch contact 48V at I 1A Max current of switch contact 2A at U 30 V Operational temperature 20 to 50 C 5 2 Mechanical dimensions dimensions Hx...

Page 32: ...Number under button 6 Day 1gr 106 16 Number under button 7 Day 1gr 107 16 Number under button 8 Day 1gr 108 16 Number under button 9 Day 1gr 109 16 Number under button 10 Day 1gr 110 16 Number under button 11 Day 1gr 111 16 Number under button 12 Day 1gr 112 16 Number under button 1 Night 2gr 201 16 Number under button 2 Night 2gr 202 16 Number under button 3 Night 2gr 203 16 Number under button 4...

Page 33: ...ch closing sec 38 2 Tone pulse tone choice 1 0 41 1 Sign of call extension 42 1 Guard hang up from phone 1 431 2 Guard hang up from phone 2 432 2 Service password 44 4 Comm to DAY switching 45 2 Comm to NIGHT switching 46 2 Guard choice mode 1 0 47 1 Keyboard connection 0 1 2 3 48 1 Keyboard mode 1 0 49 1 DTMF during talk 0 1 2 3 40 1 Number of rings for ringing 51 1 Maximum call duration min 52 1...

Page 34: ...NUDV Installation and Operating Instructions 34 ...

Page 35: ...t be energized to power supply and the guards to outputs of analogue line indicated on figure both outputs of analogue line are parallel The DistyBox300 contains an internal antenna allowing the connection of 300 m direct visibility and 50 m in building The DistyBox5000 can be fitted with an external antenna increasing the range to 6 km 7 2 DistyBox Signaling LED indication Time interval is 8sec s...

Page 36: ... internal 2 external call 72 xxx Flash length xxx times 10ms 100ms 010 firm 210ms 90 reset and company setting bold presets all 91 reset and company setting bold log in parameters will be kept 92 0 1 autoreset 0 inactive 1 active every 24 hrs will end all transmissions and recall to base station Settings for use with guard 90 401 410 700 710 Internal call will be executed by s where s is 0 9 i e n...

Page 37: ...e producer only will make the guarantee repairs Attach the description of claim reason proof of purchase and your exact address to the product The guarantee does not include mechanical thermal chemical and other damages caused by user s activities defects caused by natural disasters defects caused by repair or changes carried out by user or other unauthorized person willful damage of product incor...

Page 38: ... JR 2004 9 version V8 1 I 09 ...

Reviews: