Mode
Category
Description
Default
MCU/RCU
310
Common
Mode 310 = ON:
The monitoring timer for MP hang-
up is 6 seconds and returning a response to the host
within 8 seconds is guaranteed.
Mode 310 = OFF (default):
The monitoring timer for
MP hang-up is 8 seconds.
Notes:
1.
This SOM applies to a site where strict host
response performance is required.
2.
If a hardware failure occurs when this SOM is
set to ON, the time until MPB blockage is
determined is shorter than usual.
OFF
-
448
Universal
Replicator
When the SVP detects a blocked path:
Mode 448 = ON:
An error is assumed and the mirror
is immediately suspended.
Mode 448 = OFF (default):
If the path does not
recover within a
specified
period of time, an error is
assumed and the mirror is suspended.
Note:
SOM 448 setting is available only when SOM
449 is set to OFF.
OFF
-