Item
Content
ECC Group
Number of parity group to which the external volume is mapped.
If the number starts with "E" (for example, E1-1), the parity group contains
external volumes.
Range of values: E1-1 to E16384-4096
Current MPU
Number and name of a current MP unit controlling the parity group to
which the external volume is mapped
■
MPU-10
■
MPU-11
■
MPU-20
■
MPU-21
Setting MPU
Number and name of an MP unit
configured
to control the external volume
indicated by ECC Group
■
MPU-10
■
MPU-11
■
MPU-20
■
MPU-21
Vendor
Vendor name of the external storage system
Product Name
Product name of the external storage system
Serial Number#
Serial product number of the external storage system
Path Mode
Mode which indicates how the paths between local and external storage
systems operate
■
Multi
■
Single
■
ALUA
Port
Name of a local port from which the external path is connected to the
external storage system
WWN
Port
identifier
number of the external storage system
Blank if "Package Type" is iSCSI
LUN
LU number set for the external volume.
Priority
Priority of the paths between the storage systems to be used for
connection with the external volume.
"1" indicates the path of the highest priority.
ELunInfo.csv
Appendix A: Examples of storage
configuration
reports
System Administrator Guide for VSP Gx00 models and VSP Fx00 models