DkuTempAveInfo.csv shows the average temperature as DB temperature data. The total
number of items depends on the model (VSP G200: 17, VSP G400/VSP G600/VSP
F400/VSP F600: 49, VSP G800/VSP F800: 97).
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only),
DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum
temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output
every two hours might not contain data for the period. If a failure occurs in the storage
system, the correct information might not be output.
Table 22 DkuTempAveInfo.csv
file
(Title: <<DB temperature average Information>>)
Item
Description
Date
Year, month, and date when temperature
data was acquired in the format:
YYYY
/
MM
/
DD hh
:
mm
:
ss
DB00 DBPS001
Temperature average
Average temperature (°C) for the two-hour
period of DB00 DBPS001
DB47 DBPS472
Temperature average
Average temperature (°C) for the two-hour
period of DB47 DBPS472
For VSP G200, item shows up to DB07
DBPS072.
For VSP G400, VSP G600, VSP F400, VSP
F600, item shows up to DB23 DBPS232.
Note:
An item name is displayed as DB
xx
DBPS
xxy
. The names are listed in ascending
order of the DB number. See
for DB
xx
and DBPS
xxy.
DkuTempInfo.csv
This CSV
file
contains information about DB temperature for every two hours. A record is
DB temperature information obtained from the environment monitor. A record output to
the
first
line shows the latest temperature information. Because DB temperature
information is measured by DBPS, items are displayed in this unit*.
DkuTempInfo.csv shows the average temperature, maximum temperature, and
minimum temperature as DB temperature data. The total number of items depends on
the model (VSP G200: 49, VSP G400/ VSP G600/VSP F400/VSP F600: 145, VSP G800, VSP
F800: 289).
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only),
DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum
temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output
every two hours might not contain data for the period. If a failure occurs in the storage
system, the correct information might not be output.
DkuTempInfo.csv
Appendix A: Examples of storage
configuration
reports
System Administrator Guide for VSP Gx00 models and VSP Fx00 models
248