Mode
Category
Description
Default
MCU/RCU
745
Universal
Volume
Manager
Enables to change the area where the information is
obtained as the Characteristic1 item from
SYMMETRIX.
Mode 745 = ON:
■
The area where the information is obtained as the
Characteristic1 item from SYMMETRIX is changed.
■
When CheckPaths or Device Health Check (1/
hour) is performed, the information of an already-
mapped external volume is updated to the one
after change.
Mode 745 = OFF (default):
■
The area where the information is obtained as the
Characteristic1 item from SYMMTRIX is set to the
default.
■
When CheckPaths or Device Health Check (1/
hour) is performed, the information of an already-
mapped external volume is updated to the
default.
Notes:
1.
This SOM is applied when the EMC SYMMETRIX
is connected using UVM.
2.
Enable the setting of EMC SCSI Flag SC3 for the
port of the EMC SYMMETRIX storage connected
with the storage system and disable the setting
of Flag SPC2. If the setting of EMC SCSI Flag SC3
is not enabled or the setting of Flag SPC2 is
enabled, the
effect
of this SOM may not be
achieved.
3.
If you want to enable this SOM immediately
after setting, perform Check Paths on each path
one by one for all the external ports connected
to the EMC SYMMETRIX storage. But, without
doing Check Paths, the display of Characteristic1
can automatically be changed by the Device
Health Check to be performed once an hour. If
SSB=AD02 occurs and a path is blocked,
perform Check Paths on this path again.
OFF
-
System option modes
Appendix B: System option modes
System Administrator Guide for VSP Gx00 models and VSP Fx00 models
314